Chapter 2 Installation
2.1 Rear Panel
This diagram shows the rear panel of the CT-402.
GPON
PORT
Reset button
The installation steps for each rear panel interface is provided below.
Power Jack/Button
Press the power button to the OFF position (OUT). Connect the power adapter to
the power jack. Attach the power adapter to a wall outlet or other AC source. Press
the power button to the ON position (IN).
Caution 1:
If the device fails to power up, or it malfunctions, first verify that
the power cords are connected securely. Then power it on again.
If the problem persists, contact technical support.
Caution 2:
Before servicing or disassembling this equipment, always disconnect
all power cords and telephone lines from their outlets.
Reset Button
Restore the default settings of the device by holding down the Reset button for more
than five seconds. This may be required if the CT-402 fails to respond normally or
if you are locked out of the unit due to configuration changes.
GIGABIT LAN
Use a 1000BASE-T compliant RJ-45 cable to connect to a Gigabit LAN. This port can
also be used to connect to slower 10/100BASE-T networks. The port is auto-sensing
MDI/X and either straight-through or crossover cable can be used.
GPON PORT
Connect a single mode optical fiber to the ITU-T G.984 standard SC/APC connector.
NOTE:
Avoid looking into the port, as there is some safety risk due to laser light.
5