12

7

8

9

10

BST-75 REAR PANEL

POWER INPUT JACK:

  Requires 12V AC at 200 mA.  Will also accept 12V

DC with either positive or negative center pin (for field operation only).

CHANNEL SELECTOR SWITCH:

  Selects the frequency on which the

transmitter will operate.  (See Frequency Information Section.)

EXTERNAL ANTENNA JACK:

  BNC connector provides a standard

50 ohm RF output for use with an external antenna.

RF POWER SWITCH:

  Adjusts the RF power output of the transmitter

(High-120mW, Mid-40mW, Low-10mW).

AUDIO LEVEL CONTROL:  

This control is used to set the proper

modulation level when referenced with the VU meter.

MIC / LINE AUDIO INPUT:

  XLR-3 accepts balanced line level input.

1/4” phone jack accepts 2-conductor electret microphone type only.

11

Page 7

7

10

9

12

8

11

Содержание BST-75

Страница 1: ...Synthesized Base Station Transmitter BST 75 OPERATOR S MANUAL 72 76 MHz 357 West 2700 South Salt Lake City Utah 84115 Phone 800 496 3463 Fax 801 484 6906 www comtek com...

Страница 2: ...tion Equipment Placement Power Requirements Remote Antenna Screw in Whip Antenna Audio Input Connections Audio Adjustments Audio Processing Circuit Front and Rear Panel Facilities Frequency Informatio...

Страница 3: ...our transmitters can be installed in one rack space Also it operates in the 72 76 MHz band under FCC Regulation Part 90 This allows a greater RF power capability 120 mW for greater range and reliabili...

Страница 4: ...tation or the remote antenna as far as possible from the affected equipment Should you continue to have problems contact COMTEK s Technical Support Services for assistance Power Requirements The BST 7...

Страница 5: ...antennas and specialty antennas contact COMTEK s Technical Support Services Integral Screw in Whip Antenna If the BST 75 base station transmitter is to be used outside of the traditional rack mounted...

Страница 6: ...he transmitter must be modulating at least 50 with normal speech 0 dB on the VU meter This adjustment is made in the following manner a Ensure that the audio source has been optimized for best signal...

Страница 7: ...is however determined by the corresponding de emphasis and equalization used in the receiver In order to accommodate a greater variety of receivers the BST 75 transmitter incorporates the option to o...

Страница 8: ...the power is on VU METER Displays the audio level being used for modulation See Audio Adjustment Section ANTENNA INDICATOR Flashes when transmitter detects coaxial cable shorts and open conditions bad...

Страница 9: ...tion Section EXTERNAL ANTENNA JACK BNC connector provides a standard 50 ohm RF output for use with an external antenna RF POWER SWITCH Adjusts the RF power output of the transmitter High 120mW Mid 40m...

Страница 10: ...3 F 6 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 CHAN FREQ 72 80 MHz 72 82 MHz 72 84 MHz 72 86 MHz 72 88 MHz 72 90 MHz 72 92 MHz 72 94 MHz 72...

Страница 11: ...radio receivers to some extent when multiple transmitters are used in the same operating area The RF signals will MIX together generating additional signals If these product frequencies are too close...

Страница 12: ...age 10 BST 75 ACCESSORIES Included Accessories 1 C 75 Carrying case 2 BST 75 Operator s manual 3 TWA 75 Telescoping whip antenna 4 AP 12VAC Power adaptor 115V AC Input 5 BST 75 Base station transmitte...

Страница 13: ...mote dipole antenna 2 PRA Phase Right coaxial antenna 3 PRA Phase Right antenna mount 4 HM 100 1 4 Behind the neck directional boom microphone 5 RMK 75 4 Quad rack mount face plate 6 RMK 75 2 Double r...

Страница 14: ...cy Response 80 Hz to 10 kHz Audio Distortion Less than 0 5 at 80 modulation Modulation Limiter Peak compressor type with high linear overload protection 25 dB Attack time less than 1 ms recovery time...

Страница 15: ...ARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF SUCH EQUIPMENT INCLUDING WITHOUT LIMITATION ANY WARRANTY THAT THE USE OF SUCH EQUIPMENT FOR ANY PURPOSE WILL COMPLY WITH APPLICABLE LA...

Страница 16: ...357 West 2700 South Salt Lake City Utah 84115 Phone 800 496 3463 Fax 801 484 6906 www comtek com...