MN-CMR5975-QSG Rev 3
Copyright © 2008 Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA. All rights reserved. Printed in the USA.
Initial Configuration
The initial configuration involves setting up the IP parameters via the terminal cable. Once the IP parameters
have been configured, the terminal cable can be removed. The terminal cable should be stored in a known
location, since it may be needed in the future.
To configure the IP parameters:
Step
Procedure
1
Using a terminal emulator on a PC such as HyperTerminal™ or TeraTerm™, set up the
communication port as follows:
•
38,400
BAUD
•
8
Data
Bits
•
1 Stop Bit
•
No
Parity
•
No
Flow
Control
2
Press the
<ENTER>
key on the PC – the login prompt should be displayed.
3
The default user is “comtech” and the default password is “comtech”. After logging in, the MR-
S2’s menu should be displayed.
4
Press “
N
” for Network Menu.
5
Press “
I
” for the IP Address, Enter the IP Address and press
<ENTER>.
6
Press “
M
” for the Subnet Mask. Enter the Subnet Mask and press
<ENTER>.
7
Press “
G
” for the Default Gateway IP Address. Enter the Default Gateway Address and press
<ENTER>
.
8
Press “
S
” to save the parameters.
9
Press “
Y
” to confirm the saving of parameters.
10
Press “
X
” to exit to the main menu.
At this point, the unit has been configured for full operation and the terminal cable may be removed. The
coaxial connection to the Low Noise Block (LNB) may now be safely attached to the L-Band input port. For
continued operation the unit may be managed via the Terminal Interface; however, it is recommended to use the
Web Interface for ease of management.