background image

MN-CMR5975-QSG Rev 3 

 

Copyright © 2008 Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA. All rights reserved. Printed in the USA. 

Major Assembly

 

The Comtech EF Data Digicast Media Router CMR-5975 (MR-S2) is available in a standalone configuration. 
The following table lists the components provided with a standard configuration. In the event any listed item is 
missing, please contact Comtech EF Data Customer Support.  

Digicast Media Router MR-S2 Standalone Configuration

 

 

Quantity   Description  

1  

CMR-5975 [MR-S2]  

1  

SPU30-102 Power Supply  

1  

IEC Power Cable  

1  

CA-TERMINAL Terminal Cable 

1  

Quick Start sheet  

 

Installation 

The MR-S2 is designed for ease of installation and configuration. Once the unit has been removed from the 
packing container, please follow these instructions: 
 

Step 

 

Procedure 

 

1  

Place the MR-S2 on a flat surface with free-air flow where the LEDs can be clearly observed with unrestricted access to 
the rear panel of the unit.  

2  

It is suggested that the coaxial connection to the Low Noise Block (LNB) NOT be connected to the unit until the unit has 
been fully configured.  If the unit will not be powering the LNB, it is recommend that an F-Type DC Block be installed on 
the input to the MR-S2’s L-Band input  

3  

Connect the DC power connection to the connection labeled

 PWR

 on the back of the unit and tighten the restraining nut 

to ensure secure operation.  

4  

Connect an RJ-45 Ethernet cable (patch cord) to the port labeled 

ETHERNET

.  This cable should be connected to an 

Ethernet concentrator (hub) or switch.  

5  

Connect a terminal cable (supplied) to the port labeled 

TERM

.  This cable should be connected to a PC’s serial port (DB-

9) to initially configure the MR-S2.  

6  

Connect the AC power cord between a standard wall outlet and the power supply.  The Blue LED will illuminate.  

7  

Upon startup, the following LEDs will illuminate on the MS-R2 front panel:  

 

LED 

 

Function Label 

 

Description 

 

Blue  

PWR 

 

LED illuminates if power is properly applied  

Red  

ALARM 

 

LED may illuminate since the unit is not yet configured  

Green  

LOCK 

 

LED illuminates if the tuner is locked  

Green  

E-RX 

 

LED flashes if there is Ethernet traffic/activity  

Green  

E-TX 

 

 

Green  

E-LINK 

 

LED illuminates if the Ethernet connection to the Hub/Switch is operational  

 