About this Manual 

 

This manual provides installation and operation information for the Comtech EF Data LNA Low 
Noise Amplifier Series. This is a technical document intended for earth station engineers, 
technicians, and operators responsible for the operation and maintenance of the LNA. 

Conventions and References  

Metric Conversion 

Metric conversion information is located on the inside back cover of this manual. This 
information is provided to assist the operator in cross-referencing English to Metric conversions. 

Cautions and Warnings 

CAUTION

 

CAUTION indicates a hazardous situation that, if not avoided, may result in 
minor or moderate injury. CAUTION may also be used to indicate other 
unsafe practices or risks of property damage. 

 

 
 

WARNING

 

 
WARNING indicates a potentially hazardous situation that, 
if not avoided, could result in death or serious injury.

 

 
 

IMPORTANT

 

Indicates information critical for proper equipment 
function.  

Reporting Comments or Suggestions Concerning this Manual 

Comments and suggestions regarding the content and design of this manual will be appreciated. 
To submit comments, please contact the Comtech EF Data Technical Publications Department: 
[email protected] 

Содержание CLNA

Страница 1: ...TE The information contained in this document supersedes all previously published information regarding this product Product specifications are subject to change without prior notice LNA Low Noise Amp...

Страница 2: ......

Страница 3: ...l Part Number MN LNAS IOM Revision 0 December 14 2005 Copyright Comtech EF Data 2004 All rights reserved Printed in the USA Comtech EF Data 2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 FA...

Страница 4: ...il can be sent to the Customer Support Department at service comtechefdata com Contact us via the web at www comtechefdata com To return a Comtech EF Data product in warranty and out of warranty for r...

Страница 5: ...2 1 3 RELIABILITY 1 2 1 4 CONSTRUCTION 1 2 CHAPTER 2 INSTALLATION 2 1 2 1 UNPACKING 2 1 2 2 MOUNTING 2 2 2 3 LNA CONNECTOR PINOUTS 2 2 CHAPTER 3 FUNCTIONAL AND PHYSICAL DESCRIPTIONS 3 1 3 1 DIMENSIONA...

Страница 6: ...e 9 1 ASI And LVDS Interface Block Diagram 9 2 Figure 9 2 Rear Panel Layout 9 3 Figure 9 3 Signal Timing 9 5 Figure 10 1 1000 Base T Ethernet GbE Interface 10 1 Figure 10 2 GbE Interface Option Board...

Страница 7: ...ator in cross referencing English to Metric conversions Cautions and Warnings CAUTION CAUTION indicates a hazardous situation that if not avoided may result in minor or moderate injury CAUTION may als...

Страница 8: ...and 230 volt AC operation use T1 25A 20mm fuses FOR CONTINUED OPERATOR SAFETY ALWAYS REPLACE THE FUSES WITH THE CORRECT TYPE AND RATING Environmental The LNA must not be operated in an environment wh...

Страница 9: ...able ensure the replacement has an equivalent specification Examples of acceptable ratings for the cable include HAR BASEC and HOXXX X Examples of acceptable connector ratings include VDE NF USE UL CS...

Страница 10: ...61000 4 5 Surge Immunity EN 61000 4 6 RF Conducted Immunity EN 61000 4 8 Power Frequency Magnetic Field Immunity EN 61000 4 9 Pulse Magnetic Field Immunity EN 61000 4 11 Voltage Dips Interruptions and...

Страница 11: ...EF Data No other warranty is expressed or implied Comtech EF Data specifically disclaims the implied warranties of merchantability and fitness for particular purpose Exclusive Remedies The remedies pr...

Страница 12: ..._______________________________________________________ ______________________________________________________________________________ _________________________________________________________________...

Страница 13: ...quirements for commercial geosynchronous satellites worldwide Their compact design and rugged construction make them ideal for transportable applications and severe environments They have a comprehens...

Страница 14: ...aximum product consistency and enhanced reliability 1 3 RELIABILITY The Comtech EF Data amplifier series CLNA and KLNA utilizes proprietary circuitry and high quality components to achieve an MTBF mea...

Страница 15: ...ng tool that will extend more than 1 inch into the container This can cause damage to the LNA Unpack the LNA as follows Step Procedure 1 Cut the tape at the top of the carton indicated by OPEN THIS EN...

Страница 16: ...supplied with the following connector configurations depending on the model and options 4 pin 6 pin See Table 2 1 for pinouts of the above connectors Table 2 1 LNA Connector Pinouts 4 Pin LNA 6 Pin L...

Страница 17: ...3 1 Chapter 3 FUNCTIONAL AND PHYSICAL DESCRIPTIONS 3 1 Dimensional Envelope All dimensions are in English units centimeters are in parentheses 3 1 1 C Band LNA Figure 3 1 C Band LNA Dimensions...

Страница 18: ...CDM 710 Satellite Modulator Revision 2 Functional and Physical Description MN CDM710 IOM 3 2 3 1 2 Ku Band LNA Figure 3 2 Ku Band LNA Dimensions 25 1 122 38 1 040 1 80 1 63...

Страница 19: ...over 40 MHz KLNA 2 dB over Full Band 0 75 dB p p over 40 MHz Level 1 dB Comp 10 dBm Third Order Intercept 20 dBm AM PM Conversion 0 5 dB 5 dBm Linear Group Delay 0 01 ns MHz Parabolic Group Delay 0 00...

Страница 20: ..._____________________________________________ _____________________________________________________________________________________________ ____________________________________________________________...

Страница 21: ...103 1 609 x 103 1 609 1 mm 0 03937 1 kilometer 0 621 Temperature Conversions Units of Weight Unit Gram Ounce Avoirdupois Ounce Troy Pound Avoir Pound Troy Kilogram 1 gram 0 03527 0 03215 0 002205 0 0...

Страница 22: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...