CDM-840 Remote Router
Revision 0
Ethernet Management
MN-CDM840
5–17
5.4.4.4.3
Configuration | Mod
Figure 5-11. Configuration| Mod page
The ‘
Configuration | Mod’
page (
Figure 5-11
) permits the user to configure CDM-840 Tx
modulator operations. Note that, for any configuration item requiring text entry, a reference to the
operational ranges for that text box is provided to the right of that text box.
Modulator
The acceptable/valid operating range for each item in this section is provided in brackets.
Data Rate
[16 – 15343 kbps] – Enter the router’s Tx Data Rate in kbps.
Once the desired Tx Data Rate has been set, click
[Submit]
as needed to save this change.
Symbol Rate
[16 – 4500 ksps] – Enter the router’s Tx Symbol Rate in ksps.
Once the desired Tx Symbol Rate has been set, click
[Submit]
as needed to save this change.
FEC Type –
Presently,
VersaFEC
is the sole available FEC type.
Tx Frequency
[950 – 2150 MHz ]
–
Enter the router’s Tx frequency in MHz.
MODCOD –
Use the drop-down menu to select the Modulation type and FEC rate (
MODCOD)
.
Selections are as follows:
•
VersaFEC MODCOD 0 – BPSK 0.488
•
VersaFEC MODCOD 6 – 8-QAM 0.711
•
VersaFEC MODCOD 1 – QPSK 0.533
•
VersaFEC MODCOD 7 – 8-QAM 0.780
Содержание CDM-840
Страница 2: ......
Страница 6: ...This page is intentionally blank...
Страница 20: ...CDM 840 Remote Router Revision 0 Preface MN CDM840 xvi Notes...
Страница 32: ...CDM 840 Remote Router Revision 0 Introduction MN CDM840 1 12 Notes...
Страница 36: ...CDM 840 Remote Router Revision 0 Installation MN CDM840 2 4 Notes...
Страница 42: ...CDM 840 Remote Router Revision 0 Rear Panel Connector and Pinouts MN CDM840 3 6 Notes...
Страница 100: ...CDM 840 Remote Router Revision 0 Appendix A MN CDM840 A 4 Notes...
Страница 108: ...CDM 840 Remote Router Revision 0 Appendix B MN CDM840 B 8 Notes...
Страница 110: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...