Front Panel Operation
CDM-500 Closed Network Satellite Modem
6–22
Rev.
1.3
6.8.7
(MONIT) RX-PARAMS (Receive Parameters)
RX:EbNo=5.7dB dF=+11.7k
BER=3.4E-9 BUF-FILL=50%
If the demodulator is locked, this screen shows the following:
Eb/No This shows the value of Eb/No calculated by the demodulator.
The value referred to here is the energy per information bit
(Ebi), divided by the noise spectral density (No).
dF This is the frequency offset of the received carrier, in kHz, with
a displayed resolution of 100 Hz.
BER This is an estimate of the corrected BER. This figure is derived
from an accurate measurement of the uncorrected error rate
(from the Viterbi decoder), applied to a look-up table.
BUF-FILL (Buffer fill state) This gives the value, in percent, of the current
fill state of the Plesiochronous-Doppler Buffer. Following a
reset, it will read 50%. A value < 50% indicates that the buffer
is emptying, and >50% indicates that it is filling.
If the demodulator is not locked, this screen shows the message ‘DEMODULATOR
NOT LOCKED’. Pressing ENTER or CLEAR will take the user back to the previous
menu.
Содержание CDM-500
Страница 1: ...Part Number MN CDM500 IOM Revision 1 3 CDM 500 Satellite Modem Installation and Operation Manual...
Страница 3: ......
Страница 5: ......
Страница 25: ...Physical Description CDM 500 Closed Network Satellite Modem 4 4 Rev 1 3 This page is intentionally blank...
Страница 61: ...EDMAC Channel CDM 500 Closed Network Satellite Modem 8 4 Rev 1 3 This page has been intentionally left blank...
Страница 65: ...Spec Summary CDM 500 Closed Network Satellite Modem A 4 Rev 1 3 Figure A 1 BER Viterbi Decoding...
Страница 71: ...Remote Control CDM 500 Closed Network Satellite Modem B 6 Rev 1 3 This page is intentionally blank...
Страница 83: ...Remote Control CDM 500 Closed Network Satellite Modem B 18 Rev 1 3 This page has been intentionally left blank...
Страница 87: ......
Страница 88: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...