If the user selects ACTIVE, then a Receive Traffic fault will be generated whenever the
receive circuitry senses that the buffer has either underflowed, or overflowed.
If the user selects MASKED, no alarm will be generated under these conditions.
6.5.41
(CONFIG, MASK) TX-AIS
SEL TX-AIS ALARM MASK:
ACTIVE MASKED(PRESS ENT)
Select ACTIVE or MASKED, using the LEFT/RIGHT arrow keys, then press Enter.
If the user selects ACTIVE, then a Transmit Traffic fault will be generated whenever the
transmit circuitry senses that the ‘all ones’ condition is present in the transmit data.
If the user selects MASKED, no alarm will be generated under these conditions.
6.5.42
(CONFIG) IMPED (IF impedance)
SELECT IF IMPEDANCE:
50 OHMS 75 OHMS (ENTER)
Select 50 ohms or 75 ohms, using the LEFT/RIGHT arrow keys, then press Enter.
Содержание CDM-500
Страница 1: ...Part Number MN CDM500 IOM Revision 1 3 CDM 500 Satellite Modem Installation and Operation Manual...
Страница 3: ......
Страница 5: ......
Страница 25: ...Physical Description CDM 500 Closed Network Satellite Modem 4 4 Rev 1 3 This page is intentionally blank...
Страница 61: ...EDMAC Channel CDM 500 Closed Network Satellite Modem 8 4 Rev 1 3 This page has been intentionally left blank...
Страница 65: ...Spec Summary CDM 500 Closed Network Satellite Modem A 4 Rev 1 3 Figure A 1 BER Viterbi Decoding...
Страница 71: ...Remote Control CDM 500 Closed Network Satellite Modem B 6 Rev 1 3 This page is intentionally blank...
Страница 83: ...Remote Control CDM 500 Closed Network Satellite Modem B 18 Rev 1 3 This page has been intentionally left blank...
Страница 87: ......
Страница 88: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...