background image

15

NARC ID CENTRAL STORAGE UNIT (CSU)

 — Instructions

Caps (sold in boxes of 50; includes tags):

RF-CAP-FENTA

 (blue for fentaNYL)

RF-CAP-MIDAZ

 (orange for Midazolam)

RF-CAP-MORPH

 (purple for Morphine)

RF-CAP-HYDRO

 (green for HYDROmorphone)

RF-CAP-KETAM

 (yellow for Ketamine)

RF-CAP-MEPER

 (tan for Meperidine)

RF-CAP-DIAZE

 (gray for diazePAM)

RF-CAP-LORAZ

 (pink for LORazepam)

RF-CAP-GENER

 (white for Generic)

Capsules (sold in packs of 25):

RF-CPS-SHORT

 (short)

RF-CPS-MEDIUM

 (medium)

RF-CPS-LONG

 (long)

RF-CPS-OBLONG

 (oblong)

Tags:

RF-TAG-FENTA

 (blue for fentaNYL)

RF-TAG-MIDAZ

 (orange for Midazolam)

RF-TAG-MORPH

 (purple for Morphine)

RF-TAG-HYDRO

 (green for HYDROmorphone)

RF-TAG-KETAM

 (yellow for Ketamine)

RF-TAG-MEPER

 (tan for Meperidine)

RF-TAG-DIAZE

 (gray for diazePAM)

RF-TAG-LORAZ

 (pink for LORazepam)

RF-TAG-GENER

 (white for Generic)

Totes (sold individually with no caps or capsules):

RF-TOTE-SMALL

 (small)

RF-TOTE-LARGE

 (large)

NARC iD Central Storage Unit 

Accessories

NARC iD 

Colors for tags and caps by medicine

Pantone 311C

fentaNYL

Pantone 4525C

Meperidine

Pantone 158C

Midazolam

Pantone 2593C

Morphine

Pantone 361C

HYDROmorphone

Pantone Yellow C

Ketamine

white

Generic

Pantone 423C

diazePAM

LORazepam

Pantone 203C

Note: product images are not to scale.

Содержание eLock NARC iD

Страница 1: ...tion with existing 802 11b g n networks For complete set up instructions for networked and stand alone eLocks please see the Help section in CompX s LockView v5iDPro software Central Storage Unit dimensions with CompX eLock installed Central Storage Unit dimensions with CompX eLock components 1 NARC ID CENTRAL STORAGE UNIT CSU Instructions RFID antenna inside Control electronics Integrated motoriz...

Страница 2: ...and housing taking care around the USB connector and edges of keypad Wipe excess cleaner off of all surfaces Installation NARC iD CSU can be installed using the 6 predrilled key holes and supplied 10 x Phillips pan head screws Be sure to mount the box in a location that provides enough clearance for the doors to open The NARC iD CSU system comes with a power supply connector intended to be connect...

Страница 3: ... button 5 BACK CANCEL button 6 MENU button 7 DOWN button 8 Button 9 Button 10 Low battery indicator yellow LED 11 Alpha numeric keypad 12 HID Prox or HID iCLASS reader location if equipped 13 ENTER button 14 CLEAR button 1 2 3 4 5 6 7 8 9 10 11 14 13 12 NARC iD controller button layout NARC Box with NARC iD installed Drug Tote Capsule Controlled substance ...

Страница 4: ...uration Install Manual and the CompX LockView Software Instruction Manual before proceeding The eLock is shipped in FACTORY mode Methods to begin building a database of eLocks in CompX s LockView Software For Networked 802 11 b g or N eLocks please follow the CompX eLock Database Network Configuration Install Manual and the CompX LockView Software Instruction Manual before proceeding LockView Mode...

Страница 5: ... Lock Name has been chosen in LockView it can not be changed Please be sure the name that is chosen is the one that will be used in the future 4 Verify and or adjust all other lock parameters and click OK See LockView Instruction Manual for complete details on these options 5 Connect the eLock via the USB cable to the computer on which LockView is installed 6 After 30 seconds the lock will be upda...

Страница 6: ...p Volume RFID Test WiFi Test Use the UP and DOWN buttons to scroll through the menu choices and hit NEXT SELECT to activate one Date Time Format Choose the hour format AM PM or 24 hour by using the UP and DOWN keys to highlight the words to the immediate right of HOURS Use the and buttons to change the selection Choose the date format by using the UP and DOWN buttons to highlight the words to the ...

Страница 7: ...XT when done Contrast Use the buttons to choose the contrast of the LCD display Alternately choose 1 9 directly to choose the contrast level Press NEXT when done Beep Volume Use the buttons to choose the Beep Volume Alternately choose 1 9 directly to choose the Beep Volume Press NEXT when done RFID Test This screen will turn on the RFID antennas and show real time RFID tag reading from both antenn...

Страница 8: ...e in the NARC iD CSU system must be configured and programmed before the test See LockView Database Network Configurations Installation Manual for details This screen will turn on the WiFi system and connect to the network MAC address IP address Mask and Gateway address will be shown along with signal strength Press CLEAR to exit ...

Страница 9: ...Line up the slots in the cap and capsule to make an alignment tunnel then insert the wire from the RFID tag Insert the locking tab arrow side DOWN on the end of the wire from the RFID tag wire into the RFID tag Orientation is CRITICAL The arrow on the latch must be on the bottom locking tab arrow must be on the bottom to properly engage See color chart on page 15 for color narcotic matching 1 2 4 ...

Страница 10: ...CSU Capsule Assembly Instructions continued Place tote into NARC iD box To ensure the locking tab is fully inserted you must hear and feel a click 5 Close lid Each tote can carry a total of 15 controlled substances 7 8 6 Place capsules in tote or CSU cabinet ...

Страница 11: ...e instruction manual for information regarding adding valid users Open the door and insert a tote containing RFID enabled capsules with tags When the door is closed the NARC iD CSU system will turn on and scan the box for tags The LCD screen will say SCANNING DRUGS PLEASE WAIT It will also show how many tags have been identified confirmed After the NARC iD CSU system has completed the scan the LCD...

Страница 12: ...says NARC TAG 1 2 fentaNYL 5 244 is missing Press ENTER to continue to begin telling the NARC iD CSU system the whereabouts of the missing controlled substances Depending how the system has been configured in LockView there will be many choices available These include INCIDENT or CONSUMED EXPIRED LOST BROKEN SKIP or TRANSFER Press the UP DOWN buttons or enter the number corresponding to the wherea...

Страница 13: ... controlled substances The NARC iD CSU system assumed that the tote would be returning in the near future with some controlled substances consumed and some controlled substances still intact In this case the whereabouts of the missing narcotics are not inquired with the user until the tote is returned If however fewer than all tags are removed from the CSU the NARC iD CSU system assumes that this ...

Страница 14: ...inue to query the user about missing tags until the inventory is reconciled MALFUNCTIONING TAGS If a tag capsule cap has not been properly assembled the screen will say MALFUNCTIONING TAG REMOVE AND REPLACE When this happens remove the controlled substances that are noted on the screen Review NARC iD Capsule Assembly Instructions page 9 Verify that the locking tab is fully inserted as noted in ste...

Страница 15: ...FENTA blue for fentaNYL RF TAG MIDAZ orange for Midazolam RF TAG MORPH purple for Morphine RF TAG HYDRO green for HYDROmorphone RF TAG KETAM yellow for Ketamine RF TAG MEPER tan for Meperidine RF TAG DIAZE gray for diazePAM RF TAG LORAZ pink for LORazepam RF TAG GENER white for Generic Totes sold individually with no caps or capsules RF TOTE SMALL small RF TOTE LARGE large NARC iD Central Storage ...

Страница 16: ...nrolls and translates the narcotic name into the software w Manual inputs m Drug manufacturer m Lot number m Expiration date m Date added m Date consumed Minimum System Requirements Windows Vista 7 8 8 1 10 Server 2008 2012 and R2 versions 4GB RAM Processor 2 0 GHz or higher 8GB recommended 4GB Hard drive space SQL Server Standard Enterprise or SQL Express 2008 2012 2014 and R2 versions If install...

Отзывы: