![Computer Weld GTFM IV Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/computer-weld/gtfm-iv/gtfm-iv_operation-and-installation-manual_2647952006.webp)
1.5 Sensor
Specifications
Measurement Range
5 - 255 CFH (2 - 120 LPM)
Display Resolution
±1 CFH (± 1 LPM)
Accuracy
±2 % of full-scale ±1 digit
Operating Pressure
50-PSI maximum (344 KPA)
Fault Relay Output:
N.O. Dry Contact Closure
Relay Rating
120 vac @ 0.5 amps non-inductive, 24 vdc @ 1.0 amps non-
inductive
Analog Sensor Output:
0 - 2.55 vdc @ 10 ma.
Analog Scaling
0.01 vdc = 1 CFH (.01 V = 1 LPM)
Power Requirement
10 - 28 vdc @ 100 ma.
Operating Temperature
20° - 140° F
(-7° - 60° C)
Battery Charger
120 vac 60 hz @ 300 ma (220 VAC 50 hz @ 300 ma)
Battery Life
Approximately 2 hours with full charge
(English / Metric units of measurement available)
Note: Specifications subject to change without notification.
1.6 Models
The following models are covered in this document:
Part No.
Description
A0A0032
120 VAC Portable GTFM IV
™
System
A0A0033
240 VAC Portable GTFM IV
™
System
A0A0064
ADM IV
™
GTFM IV
™
System
A0A0036
120 VAC In-Line GTFM IV
™
System
A0A0037
240 VAC In-Line GTFM IV
™
System