Wiring Details
Details
Blue: (-) Programmable Output 2
- This wire provides a programmable negative (-) output that can
be programmed on the Drone’s Option Menu. Please see the Special Option Group 2 Menu for
details. At default setting this wire acts as a door unlock output. This wire is not available in Type 2
installations. You must wire a relay to provide a positive (+) output.
Orange: (-) Programmable Output 3
- This wire acts as a programmable negative (-) output for the
Drone. Please see the Special Option Group 2 Menu for details. At the default setting this wire will
send a negative parking light output. This output assists with programming of the remotes and Drone
options. This wire is not available in Type 2 installations.
Brown: (-) Programmable Auxiliary Trigger Input
- See option 2-05. This wire acts as a
programmable negative input for the Drone. At default it will take a negative 5 pulse trigger. It can
be programmed to take a negative latched input or negative half second negative trigger on this wire
will send and alarm triggered notification to the web interface and user’s smartphone. This wire is not
required in Type 2 installations.
4 Pin Antenna Port
- This plug is intended to connect to a Firstech compatible antenna from a
compatible RF Kit. This is used if using Drone as a standalone piece as shown in Type 1 installations.
You can also use this port to connect the OP500 Option Programmer and set options. Do not use
both 4 Pin and 6 Pin Antenna Ports at the same time.
6 Pin Antenna Port
- This plug is intended to connect to a Firstech compatible antenna from a
compatible RF Kit. This is used if using Drone as a standalone piece as shown in Type 1 installations.
You can also use this port to connect the OP500 Option Programmer and set options. Do not use
both 4 Pin and 6 Pin Antenna Ports at the same time.
RS232 Port
- This port is used when connecting to a Drone compatible bypass module. The DR-2000
supports both ADS and Fortin bypass modules. (See Option 2-06) This port is typically used in Type 1
installations.
Copyright 2011 Firstech, LLC. | 8
DR-2000 Install Guide