52
Parity Check
DATA BITS 8
↑
PARITY NONE
→
or
←
PARITY ODD
→
or
←
PARITY EVEN
→
or
←
PARITY MARK
→
or
←
PARITY SPACE
→
or
←
↓
HANDSHAKE DTR
PARITY NONE
Data does not have a parity bit, i.e. 8 bit data are transferred and the parity
check is disabled.
PARITY ODD
Parity check is enabled for odd parity.
PARITY EVEN
Parity check is enabled for even parity.
PARITY MARK
Parity check is disabled and the transmitted parity bit is always a Mark.
PARITY SPACE
Parity check is disabled and the transmitted parity bit is always a Space.