manualshive.com logo in svg
background image

 

 

BASIC CALIBRATION INSTRUCTIONS 

 
 

The calibration instructions below are given, based on the instrument being set 
up prior to being shipped to you. The instrument will have been set up based 
on the information supplied regarding the model, capacity and application the 
forklift is being used.  
This instrument can be used in a large variety of applications and changing the 
parameters that are set will greatly affect the performance of this instrument in 
the application you have indicated.  
NOTE- To exit the calibration mode without saving, turn the power off to the 
indicator.  
 

Step 1. 

– 

Ensure you have an accurate test weight of approx 1/3 

– ½ of the 

machine capacity. The more accurate the test weight, the more accurate the 
scale 
 

Step 2 

– 

Start the forklift or loader, and the CL2000MKII should also turn on. 

The indicator should power up and go through a short power up cycle. Once 
the power up cycle finishes, the indicator will show a random reading in the 
“Current Load” screen. To ensure you have the hydraulic pressure transducer 
fitted correctly, raising of the forks or bucket should result in the figure on the 
screen rising.    
 

Step 3- 

Press the 

“Menu” button on the bottom right-hand corner of the screen 

to enter the Menu screen.   
 

Step 4 

– 

Press 

the “Calibration” to enter the setup code. Enter the code 4482 

using the up, down, left, right arrows. Then Press the 

“Exit” button. You will 

now be in the Calibration Page. 

Press “Weighing Calibration” to enter the 

Weighing Calibration page.   
 

Step 5 

– 

Raise the empty Forks or Bucket to your weighing height. (Raise to 1, 

Lower to 2) Allow approx 2-3 seconds for the weight to settle, 

Press “Set 

Empty Calibration

” on the screen to set the Zero Calibration

 

 

 

Step6 

– 

Place your test weight onto the forks or bucket. 

Don’t lift to weighing 

height at this stage.  

Enter the test weight amount to “Known Load” using the 

Up, Down keys.

  

 

 

Содержание CL2000MKII

Страница 1: ...N and OPERATING INSTRUCTIONS for the COMPULOAD CL2000MKII Series LOAD WEIGHING SYSTEM For forklift or small loader application Instant Weight Pty Ltd P O Box 2340 MIDLAND WA 6936 Tel 08 9274 8600 Emai...

Страница 2: ...2 INDEX Introduction Installation Instructions Basic Calibration Basic Weighing WARRANTY...

Страница 3: ...klifts and small wheel loaders Operating Voltage is 12 24Volts DC The CL2000MKII will generally be installed with a Hydraulic pressure transducer mounted in the Lift Circuit of the machine hydraulics...

Страница 4: ...cessary FITTING THE COMPULOAD TO THE OPERATORS CABIN Select a suitable location and using the mounting bracket as a template drill two holes and mount the bracket into position Allow room for the cabl...

Страница 5: ...ff point Failing this the system will have to be entered by direct drilling and tapping into a suitable hydraulic connection Ensure the suitable hydraulic connection tee piece elbow or similar is remo...

Страница 6: ...6 Transducer connector instructional video Transducer Connector Diagram Transducer Green...

Страница 7: ...rown Power White Earth Green TXD ESTABLISHING A WEIGHING POINT Static mode When weighing in the static method a predetermined weighing point must be established The weighing point on a standard forkli...

Страница 8: ...When lowering to position 2 this must be done smoothly and slowly to allow the hydraulic pressure to be consistent Lowering abruptly will cause a pressure spike within the lift circuit and readings wi...

Страница 9: ...d power up and go through a short power up cycle Once the power up cycle finishes the indicator will show a random reading in the Current Load screen To ensure you have the hydraulic pressure transduc...

Страница 10: ...he Zero Step 5 and the Test Weight again Step 9 Press the Exit button one press at a time to return to the main weighing page and to save the calibration Perform as many test weighings until you are s...

Страница 11: ...se to 1 Lower to 2 and on the carriage Arrow or other markings on a loader 1 With the forks empty and mast upright raise forks up to the weighing position If other than 0 00 zero is displayed press ZE...

Страница 12: ...te further buckets 4 To CLEAR the TOTAL press the CLEAR button and HOLD for 3 seconds The TOTAL will return to zero to allow the next Load to be completed 5 NOTE pushing the CLEAR button once will del...

Страница 13: ...Date each bucket load and bucket number When the CLEAR button is pressed for 3 seconds at the end of a load the docket will finalise and print out a Total 2 PRINTER OFF Whilst loading the printer will...

Страница 14: ...print most likely you have the paper upside down Thermal Paper only prints on one side DO NOT PULL THE PAPER THROUGH THE PRINTER THIS WILL STRIP THE GEARS OF THE PRINTER AND CAUSE DAMAGE THAT CANNOT...

Страница 15: ...ns are carried out or attempted to be carried out by other than ATLAS WEIGHING Pty Ltd The warranty is not transferable and applies only to the original purchaser unless authorised by ATLAS WEIGHING P...

Отзывы: