11
■
Wait:
Set the length of time, in seconds, to wait after this CEC
Automation Event has been activated before ANY other
Automation Event can be detected.
■
CEC Command:
Set the CEC command to send when the
specified Automation Event is activated. Clicking the
“Test”
button will send the command immediately. Available CEC
commands are:
–
Power Off:
Turn off the connected HDMI display device.
–
Power On:
Turn on the connected HDMI display device.
–
Active Source:
Force the connected HDMI display device
to switch to the HDMI input that this unit is connected to.
Note: Not all HDMI devices support all CEC commands.
■
RS-232:
Enable or disable sending an RS-232 command when
the currently selected Automation Event is activated.
Note: The RS-
232 port must be in “Control” mode to
send
commands to external devices.
■
Delay:
Set the length of time, in seconds, that the specified
Automation Event must continue to be true before sending the
defined RS-232 command.
■
Wait:
Set the length of time, in seconds, to wait after this RS-
232 Automation Event has been activated before ANY other
Automation Event can be detected.
■
RS-232 Command:
Click the Edit icon ( ) to define the RS-232
command to send when the specified Automation Event is
activated. Clicking the “Test” button will send the
command
immediately.
2)
RS-232 Setting:
Provides controls to configure the settings and
behavior of the RS-232 port.
■
Mode:
Switch the behavior of the RS-232 port between
“Console” and “Control”. When “Console” is selected, the
unit
can receive and be controlled directly via RS-232 commands.
When “Control” is selected the RS
-232 port can send
Automation commands to control other devices.
■
RS-232 Setting Edit:
Click on the Edit icon ( ) to configure the
various RS-232 port settings including baud rate, data length,
parity and stop bits.