Страница 1: ... either valve is 180 out of phase flip toggle switch on rear of Valve Actuator from ON1 to ON2 position Turn HEAT Switch to SPA position and check that heater has been activated Turn AUXl and AUX2 Switches ON and verify that auxiliary equipment has been activated The system is now ready to be operated as desired a PAC FA6 Company Cornpool Inc 599 Fairchild Drive Mountain View California 94043 800 ...

Страница 2: ......

Страница 3: ...ffect from the spa into the pool while the system is in pool mode The effect will however cease whenever the system is in spa mode To enable this feature install a Spa Waterfall Control model RLY WTRFL at the LX 30 Power Center in accordance with instructions provided FREEZE PROTECTION A Recirculating Freeze Sensor model FPS C may be added to the system It will protect the plumbing and equipment f...

Страница 4: ...rmal protection All high voltage connections are made to terminal blocks which are located behind service panel in right side compartment of LX 30 Power Center A high voltage wiring label is located adjacent to terminal blocks Knock out holes are provided on bottom of enclosure for conduit mounting To reduce the risk of electric shock provide a continuous green insulated copper wire no smaller tha...

Страница 5: ...ify the twisted pairs and assure correct connections Strip insulation of each wire and connect to appropriate screw terminals in accordance with wiring diagram Pay attention to the two different wiring possibilities for either a dual thermostat or a single thermostat heater See Pages 6 and 8 NOTE For the convenience of the Pool Serviceperson the screw terminal can be unplugged from the circuit boa...

Страница 6: ...lated jumper wire between HTS1 and HTSP screw terminals on circuit board in accordance with wiring diagram below SINGLE THERMOSTAT GAS HEATER lnside the gas heater interrupt wire between thermostat and gas valve and connect 2 conductor cable in series with the heater circuitry at Fireman s Switch terminals if provided Do not disconnect or bypass the flow pressure or high limit switches Place the h...