Compool Lx220 Скачать руководство пользователя страница 11

9

Compool Lx220

Operating Instructions

Water Flow To Panels Switch

AUTO: Automatically turns system on whenever solar energy is available. Switch should be 
left in this position during normal use.

OFF: Manually turns solar system off.

ON: Manually turns solar system on, regardless of solar availability. This position should be 
used only to test system operation.

Water Temperature Dial

Allows solar system to heat the water up to set temperature. After that temperature is reached, 
the solar system is automatically turned off. The Dial ranges from approximately 74 - 110 
degrees Fahrenheit

To determine your optimum temperature setting, set Dial to the “HOT” position and observe the 
water temperature over a period of a few days. When the maximum desired temperature of the 
pool is reached, rotate the Dial counterclockwise until the SOLAR ON Light just goes out. Once 
this setting is identified, it will not be necessary to change the Dial.

Power On Light

When Lit, indicates that electrical power is applied to the Control.

Solar On Light

When lit, indicates that solar system is on. Note: the filter pump timer must be set so that the 
filter pump operates during that time of the day when solar energy is available.

Pool Cleaner Delay Expired Light

Whenever the solar system is turned on, an electronic delay automatically turns off the pool 
cleaner for a few minutes. This protects the pump from damage caused by air in the solar panels 
at system start-up. Note: to enable this feature, an optional Relay Kit (model RLY-SC) must be 
added to the Control. This light indicates that the delay has expired.

Содержание Lx220

Страница 1: ...Compool Lx220 SOLAR CONTROL SYSTEM Installation Operating Instructions 03 22 00 941 0809...

Страница 2: ......

Страница 3: ...Actuator 8 System Start up 8 Operating Instructions 9 Water Flow To Panels Switch 9 Water Temperature Dial 9 Power On Light 9 Solar On Light 9 Pool Cleaner Delay Expired Light 9 Water Solar Sensor Ser...

Страница 4: ...nless they are closely supervised at all times WARNING Water in excess of 100 degrees Fahrenheit may be hazardous to your health A green colored terminal marked G is located inside the high voltage co...

Страница 5: ...vailable If the Swimming Pool utilizes a pool cleaner booster pump the Control will optionally disable the pump for a period of 4 minutes whenever the solar system turns on This protects the pump from...

Страница 6: ...are mounted in a way that gravity will allow draining whenever the filter pump is not on For systems with glazed panels damage can occur from overheating if the filter pump is still running after the...

Страница 7: ...appropriate screws through the three external mounting points located on the side of the enclosure Valve Actuator Mount Valve Actuator to solar valve using the 4 mounting screws provided Run cable to...

Страница 8: ...at the solar panel array or any sunny location WARNING DO NOT DRILL HOLE AND CLAMP SENSOR INTO SOLAR PIPE For glazed panels install Sensor between collector and glazing Run 2 conductor cable between t...

Страница 9: ...accordance with instructions provided and plug low voltage connector onto circuit board at SWP Socket Using wire nuts connect Black wires to Load connections of Pool Cleaner Time Clock and connect Re...

Страница 10: ...or is operating correctly Check that Solar Valve is in solar bypass position diverting water away from solar panels If Solar Valve is staged incorrectly ie diverting water to the solar panels reverse...

Страница 11: ...over a period of a few days When the maximum desired temperature of the pool is reached rotate the Dial counterclockwise until the SOLAR ON Light just goes out Once this setting is identified it will...

Страница 12: ...T Push To Reset Power Button An internal circuit breaker protects the Solar Valve and control circuitry from electrical overload situations A tripped breaker is indicated by a white tab Check for shor...

Страница 13: ...ct the appropriate cable and wire connections and replace the appropriate Temperature Sensor if necessary An ohm meter can be used to take a reading of the Temperature Sensors See Table 1 If the Tempe...

Страница 14: ...0 Table 1 DEG F OHMS 30 34574 35 30008 40 26109 45 22771 50 19906 55 17440 60 15314 65 13477 70 11884 75 10502 80 9299 85 8250 90 7333 95 6531 100 5827 105 5208 110 4663 115 4183 120 3758 125 3382 130...

Страница 15: ...Inc or which have been damaged because of a defect in a component or part which is not part of the Compool Control System or upon which the serial number or manufacture date has been altered effaced...

Страница 16: ...Illuminate 11 Problem Solving 11 Push To Reset Power Button 10 Safety Notice 2 Second Valve Actuator 8 Solar Booster Pump Control 7 Solar Control 5 Solar On Light 9 Solar On Light Does Not Illuminate...