background image

Replacing batteries

 

 

1.

 

The Led indicator flashes continuously when battery life is ending. 

2.

 

Please change batteries at this time. 

3.

 

Select 6 AA alkaline batteries, new and old batteries can't be used 

together. 

4.

 

Open the battery box cover, remove the batteries and replace all 

batteries with new ones. 

5.

 

Please make sure you install the batteries in the right direction, the + and 

- side are indicated in the battery holder. 

6.

 

Re-position the battery box (take especial care not to pinch the cable), 

put the battery box cover back in place and tighten the screws. 

7.

 

Follow the instructions for setting the sensor range and volume of liquid 

if required. 

Wall bracket dimensions

 

 

 

 

 

 

 

 

 

 

 

 

84,5mm 

3,33 

 

 

~ 205mm 

8,07in 

 

 

80mm 

3,14in 

 

 

 

 

 

Unplug the cable and 

remove the battery box 

cover. 

 

 

 

Remove the old 

batteries and 

replace with new 

ones. 

 

 

 

Put the battery into the 

battery box according 

"+" "-"  direction. 

 

 

 

 

58mm 

2,28in 

 

28,5mm 

1,12in 

Содержание KS15-2020

Страница 1: ... gel dispenser Please read this user manual carefully before installation and retain for future reference 2020 Component Hardware Group Component Hardware reserves the right to make any and all changes and to discontinue any of its products without notice Not responsible for typographical errors ...

Страница 2: ...justable distance Sensor distance can be adjusted according to requirement Dispensed liquid volume is adjustable Designed with SCM Software Configuration Management Specification Model KS15 2020 Power supply 9V DC 6x 1 5V DC AA battery Liquid viscosity range cp 1 3500 1800 recommended Liquid capacity ml 650 Liquid alcohol content Tested to 75 Supply volume per drop ml 0 8 6 5 adjustable Flowing ti...

Страница 3: ...tion instructions on page 5 8 Pleaseposition the dispenser out of the sun s reach as much as possible WARNING 1 The dispenser could arrive in dormant mode and will initially not respond In this case please hold the reset settings button for more than 2 seconds the Led indicator will show for 3 seconds putting the unit into normal operation mode 2 Before first use please run the commissioning cycle...

Страница 4: ...t name KS15 2020 Key Top cover Battery Box Seal Battery Box Cover Gel Container Cap Protector Led Indicator Bottom View Gel Dispensing nozzle Sensor lens Reset Settings button Gel Container Wall Bracket 3 ...

Страница 5: ...Wall bracket dimensions 84 5mm 3 33 205mm 8 07in 80mm 3 14in 58mm 2 28in 28 5mm 1 12in 4 ...

Страница 6: ...Installation drawing Suggested positioning If to be installed above glossy stainless steel surfaces the distance from sensor window to surface must be over 35cm 5 ...

Страница 7: ...e plastic plugs into these holes 2 Position the wall bracket and fix it to the wall with the screws supplied 3 Position the dispenser onto the wallbracket 4 Pushthe dispenser downwards make sureitfits intothe hook tightly 5 Secure the dispenser on the wall bracket with the set screw 6 Close the dispenser with the top cover and lock it with the key 6 ...

Страница 8: ...Please make sure you install the batteries in the right direction the and side are indicated in the battery holder 6 Re position the battery box take especial care not to pinch the cable put the battery box cover back in place and tighten thescrews 7 Follow the instructions for setting the sensor range and volume of liquid if required f Unplug the cable and remove the battery box cover Remove the ...

Страница 9: ...ith the key provided 5 Put your hand under the sensor window when the sensor detects the Led indicator will flash and liquid dispensesautomatically 6 Hold the reset settings button for more than 2 seconds at first use and activate the sensor until the liquid isdispensed Note Please remove the masking from the sensor lens before first use Please add liquid tothe dispenser as above Please put your h...

Страница 10: ...nder the dispenser at the desired distance to set The Led indicator will confirm with 4 slow flashes d The sensor distance is now set to the required level Note The sensor distance should be 5 15cm 2 Adjustment of dispensingvolume You can change the dispensing volume if you require more or less liquid a Put the dispenser in settings mode please note 1a above b When in settings mode press the reset...

Страница 11: ... Led indicator does not work Dispenser is in dormant state Switch off dormant state p 2 Sensor distance is too short Adjust to longer sensor distance The batteries do not function Check batteries and change if required Sensor window is not clean Clean sensor window Sensor failure Replace sensor Led indicator works but liquid is not dispensed Sensor is switching continuously Remove any barriers in ...

Страница 12: ......

Отзывы: