Features
Hygienic:
Touchless Technology assisting a safer and cleaner work and living
environment.
Material:
304 stainless steel shell and wall bracket.
Design:
Top cover can be locked, facilitating a tamper proof device.
Electronic parts are sealed, moisture and waterproof.
Installation:
Suitable for all public and domestic areas, including hotels, public
buildings, schools, stations, hospitals, bars, restaurants, health
care and households.
Adjustable distance:
Sensor distance can be adjusted according to requirement.
Dispensed liquid volume is adjustable:
Designed with SCM (Software Configuration Management).
Specification
Model
KS15-2020
Power supply
9V DC (6x 1.5V DC AA battery)
Liquid viscosity range [cp]
1-3500
(*)
(1800 recommended)
Liquid capacity [ml]
650
Liquid alcohol content [%]
Tested to 75%
Supply volume per drop [ml]
0,8 - 6,5 (adjustable)
Flowing time [s]
0,5-2 (adjustable)
Detecting distance [cm]
5-15cm (adjustable)
Ambient operating temperature [°C]
1-45
(*) at viscosities exceeding 1800cp, it is recommended to keep the liquid volume in the
dispenser above 50% of the gel container capacity.
Troubleshooting
Caution
1. The electronics are sensitive to mechanical shock, please refrain from any
mechanical or violent interference with any part of this dispensing unit.
2. To avoid corrosion of the product's surface or inner electric components
being damaged, please use soft cloth with neutral liquid to clean its surface.
Then use damp cloth to wipe off any residual liquid, dry off with soft cloth.
Don't use water or any soap detergent which includes abrasive powder
with high acidity / alkalinity. Avoid nylon brushes etc. Please make sure
that the glossy cover of the sensor window is not scuffed, scratched or
damaged in any way to prevent the sensitivity being reduced.
Problem
Cause
Solution
Led indicator
does not work
Dispenser is in dormant
state
Switch off dormant state (p.2)
Sensor distance is too
short
Adjust to longer sensor
distance
The batteries do not
function
Check batteries and change if
required
Sensor window is not
clean
Clean sensor window
Sensor failure
Replace sensor
Led indicator
works but liquid
is not dispensed
Sensor is switching
continuously
Remove any barriers in front
of the sensor
Sensor distance is too
long
Adjust to a shorter sensor
distance
Dispenser is clogged.
Run commisioning cycle (p.2)
Liquid volume <50%
Fill gel container.
Dispenser failure
Contact your supplier
Liquid volume is
not enough
Dispensing time is too
short
Adjust it according to this
manual
Liquid viscosity is too
high
Use lower viscosity liquid
Liquid is clogging
Use it continuously until it
works, if not working, call
your supplier
Gel container is empty
Refill the gel container
1