FORWARD

This manual has been written for the owners and operators of the Compex® Wired 3.0. It contains 

general instructions for operation, precautionary instructions, and maintenance recommendations. 

In order to obtain maximum life and efficiency from your Compex® Wired 3.0, and to assist in the 

proper operation of the unit, read and understand this manual thoroughly.
The specifications put forth in this manual were in effect at the time of publication. However, 

changes to these specifications may be made at any time without obligation on the part of DJO, LLC.
Before starting any program, you should become acquainted with the compex.com website to 

establish an appropriate training plan.
The compex.com website helps you take your first steps with the device.

ABOUT COMPEX® WIRED 3.0

PRECAUTIONARY INSTRUCTIONS

The precautionary instructions found in this section and throughout this manual are indicated 

by specific symbols. Understand these symbols and their definitions before operating this 

equipment. The definitions of these symbols are as follows:

PRECAUTION

Text “PRECAUTION” indicates a situation which, 

if not avoided, may result in minor or moderate 

injury to the user or patient or damage to the 

equipment or other property.

WARNING

A warning indicates a situation which, if not 

avoided, could result in death or serious injury

NOT MADE WITH  NATURAL RUBER LATEX

DANGEROUS VOLTAGE

Text with a “Non-Ionizing Electromagnetic Radiation” 

indicator informs the user of possible hazards 

resulting from elevated, potentially dangerous 

levels of non- ionizing radiation.

DANGEROUS VOLTAGE

Throughout this manual, “NOTE” may be found. 

These Notes are helpful information to aid in the 

particular area or function being described.

CONTRAINDICATION

A contraindication indicates a condition or 

situation in which a device should not be used.

NOTE

 DANGEROUS VOLTAGE

Text with a “Dangerous Voltage” indicator serves 

to inform the user of possible hazards resulting in 

the electrical charge delivered in certain program 

configurations of waveforms.

INDICATIONS FOR USE

•  EMS: The Compex® Wired 3.0 is intended to stimulate healthy muscles in order to improve 

or facilitate muscle performance. The work imposed on the muscles by the Compex® Wired 

3.0 programs is not suitable for rehabilitation or physiotherapy.

•  TENS: The Compex® Wired 3.0 TENS is intended for:
•  Temporary relief of pain associated with sore and aching muscles due to strain from 

exercise or normal household and work activities

•  They symptomatic relief and management of chronic, intractable pain and relief of pain 

associated with arthritis.  The Compex® Wired 3.0 is an Over-The-Counter device to be used 

by adults only.

•  The Compex® Wired 3.0 is an Over-the-Counter device to be used by adults only.

CONTRAINDICATIONS

The Compex® Wired 3.0 should not be used on:

•  Painful muscles
•  Atrophied muscles
•  Muscles with spasms
•  Muscles associated with a limb with a painful or afflicted joint

The Compex® Wired 3.0 should not be used:

•  For muscle reeducation
•  To prevent or retard disuse atrophy
•  To prevent venous thrombosis
•  To maintain or increase range of motion
•  For muscle spasms
•  For blood flow deficiencies

Do not use the Compex® Wired 3.0 if you have one or more of the following medical conditions:

•  This device must not be used on persons with cardiac pacemakers, defibrillators, or other 

implanted metallic or electronic devices.

•  Cardiac demand pacemakers
•  Epilepsy
•  Following acute trauma or fracture
•  Following recent surgical procedures
•  Critical ischemia of lower limbs
•  Abdominal or inguinal hernia
•  Cancerous lesions
•  Pregnancy (do not use on abdominal region)
•  Serious arterial circulation problems in lower limbs
•  Sensitivity problems or unable to express yourself

Содержание WIRED 3.0

Страница 1: ...WIRED 3 0 Muscle Stimulators Edge 3 0 Performance 3 0 Sport Elite 3 0 READ THE MANUAL BEFORE OPERATING THIS PRODUCT...

Страница 2: ...ody parts required for normal function Critical ischemia of lower limb Seriously compromised oxygen carrying blood flow to the legs feet and toes lower limb that may result in loss of the limb if left...

Страница 3: ...contraindication indicates a condition or situation in which a device should not be used NOTE DANGEROUS VOLTAGE Text with a Dangerous Voltage indicator serves to inform the user of possible hazards re...

Страница 4: ...lation session on a person who is standing The first five minutes of stimulation must always be performed on a person who is sitting or lying down In rare instances people of a nervous disposition may...

Страница 5: ...ive medium or alternate electrode placement If you have suspected or diagnosed heart disease you should follow precautions recommended by your physician If you have suspected or diagnosed epilepsy you...

Страница 6: ...imulation accurately reproduces the process observed during a voluntary contraction The stimulator sends an electrical current impulse to the nerve fibers exciting them This excitation is then transmi...

Страница 7: ...referred to as gates These gates determine which impulses are allowed to continue to the brain The gates prevent the brain from receiving too much information too quickly Since the same nerve cannot...

Страница 8: ...cm 12 9mA in Always turn off the stimulator before moving or removing any electrodes during a session Do not place the electrodes in water Do not apply solvents of any kind to the electrodes For best...

Страница 9: ...ecome directly accessible after turning on the device NOTE Programs vary depending on device The programs done will automatically be placed in the favorites menu The favorites menu can contain up to 1...

Страница 10: ...r selection A Select the desired level B Confirm your selection C Return to the previous step Note if the level option in setting is turned off this step would be canceled D HOW TO ACCESS SETTINGS The...

Страница 11: ...eans the corresponding channel is selected After user choose the desired channel press the central confirmation button to confirm your selections then follow the tips on screen press up to start to pr...

Страница 12: ...phase relaxation cycle These are warm up recovery or even pain type program During this type of program frequency variations can occur A Warm up phase B Work phase C Relaxation phase D Recovery phase...

Страница 13: ...y is completely discharged It is no longer possible to use the device Recharge it immediately The charge state of the battery is indicated by a small battery icon on the top right screen A BATTERY LEV...

Страница 14: ...pe of effort are for example the 400 and 800 meters one kilometer cycle races and 100 meters swimming It is appropriate for many other sports based on duration such as cycling which makes repeated dem...

Страница 15: ...by placing the electrode connected to the positive pole red connection strategically When working with a muscle stimulation program involving muscle contractions it is important to place the positive...

Страница 16: ...th others When removing your pads from your skin peel from the side of the pad Do not pull the pad off by the wire When you store your electrode pads after your session make sure to stick them on the...

Страница 17: ...ls REACH Caution This is an indication for protection against ingress of water and particulate matter The mark IP22 on your unit means your unit is protected against solid foreign objects of 12 5mm di...

Страница 18: ...11 RF Emissions Group 1 The Compex Wired 3 0 uses RF energy only for its internal operation Consequently its RF emissions are very low and are unlikely to interfere with any adjacent electrical device...

Страница 19: ...ngth in the location in which the Compex Wired 3 0 are used exceeds the applicable RF compliance level above the Compex Wired 3 0 should be observed to verify normal operation If abnormal performance...

Страница 20: ...ilure in the Product caused by product misuse including but not limited to the failure to provide reasonable and required maintenance or any use that is inconsistent with the Product User Manual COMPA...

Страница 21: ...40 41 CONTACTINFORMATION Distributed By DJO LLC 1430 Decision Street Vista CA 92081 1 877 266 7398 877 COMPEX8 JKH Health Co LTD Shajing Baoan District Shenzhen China Made in China...

Страница 22: ...t 2020 by DJO LLC Individual results may vary Neither DJO LLC nor any of its subsidiaries dispense medical advice The contents of this document do not constitute medical advice Rather please consult y...

Отзывы: