A
A
Heat pump pool heater _8
HEAT PUMP POOL HEATER INSTALLATION
Determining Optimum Location
Choose a location where the noise of the heat pump when running and the discharged air do not disturb any neighbors.
Install the Pool Heat Pump Heater unit on a flat, stable surface that can support its weight and does not generate any
unnecessary noise and vibration.
Clearance
Choosing the location of your heat pump is very important. You should install it as close as possible to the filter system.
You should obey the clearance distances around the heat pump that are given in the drawing below.
Level Placement
We recommend that you install your heat pump on a solid base, for example two concrete tiles. Four (4) rubber pads
(absorbent pads) are provided to lessen the transfer of vibrations. (See drawing below.)
If the pipes are buried over a distance greater than 2 metres, they should be insulated to avoid a significant loss of energy.
A:
absorbant pads
Open field with no obstacles
30 cm or more
60 cm or more
30 cm or more
40 cm or more
B
A:
Absorbant pads
B:
Concrete tile
Bomba de calor eléctrica de bajo consumo _63
MANTENIMIENTO
Para un rendimiento óptimo de la bomba de calor, siga las siguientes instrucciones:
Lave regularmente el filtro de la piscina contracorriente para que el caudal de circulación del agua sea constante en la
bomba de calor.
Mantenga la superficie del serpentín (evaporador) limpia y sin restos de papel, hojas u otros desechos. Los puede quitar
fácilmente con un chorro de agua de baja presión sin dañar las aletas de aluminio.
Limpie cuidadosamente el aparato con un limpiador suave no abrasivo y sin blanqueador (lejía); enjuáguelo con una
manguera sin lanza de riego.
Advertencia:
Antes de efectuar cualquier tipo de trabajo en la bomba de calor, corte la corriente con el disyuntor del circuito de
alimentación eléctrica