background image

VAX 7000 Model 810

VAX Systems   4.39

Specifications

Physical Characteristics Operating

Shipping

Height
Width
Depth
Weight, full configuration
Without batteries
With batteries

170.0 cm (67.0 in.)
80.0 cm (31.5 in.)
87.5 cm (34.4 in.)

408 kg (900 lb)
545 kg (1200 lb)

195.0 cm (76.7 in.)
109.5 cm (43.1 in.)
121.0 cm (47.5 in.)

448 kg (1000 lb)
585 kg (1300 lb)

Clearances

Operating

Service

Front
Rear

1.0 m (40 in.)
1.0 m (40 in.)

1.5 m (59 in.)
1.0 m (40 in.)

Environmental

Operating

Nonoperating

Temperature
Humidity
Altitude
Vibration
Heat dissipation

1

15° to 28° C (59° to 82°F)
20% to 80%
0–2.4 km (0–8000 ft)
2–22 Hz @ 0.01"da minimum
Fully Configured System
(System Cabinet)
17,700 Btu/hr, 5,200 W
Minimally Configured System

2

(System Cabinet)
3,400 Btu/hr, 1,000 W

-40° to 66° C (-40° to 151°F)
10% to 95%
9,100 m (30,000 ft)
22–500 Hz @ 0.25g maximum
Fully Configured System
(System Cabinet with Two
I/O Expansion Cabinets)
47,000 Btu/hr, 13,800 W

Power requirements

3

U.S./Canada

Europe/APA

Japan

Nominal voltage
Frequency range
Phases

Maximum input
current/phase
Surge current
Rating
Power cap (system)
Receptacle (site)
Receptacle
PCS/PDS/PDU/UPS cable

120/208 V
50–60 Hz
3-phase star
4-wire N-GND

24 A rms

50 A peak
30 A
DEC 12-12314-00
DEC 12-12315-01
NEMA L21-30R
BC24W

380–415 V
50–60 Hz
3-phase star
4-wire N-GND

12.8 A rms

50 A peak
16 A
DEC 12-30333-02
See footnote 4
IEC309
BN29X

202 V
50–60 Hz
3-phase delta
4-wire mid-GND or
3-wire junction-GND
24 A rms

50 A peak
30 A
DEC 12-12314-00
DEC 12-12315-01
NEMA L21-30R
BC24W

 

1.Power system provides unity power factor which allows full use of input line current

(watts=VA).  Approximate Btu's for a given system configuration can be calculated by
multiplying the “EPU” value per cabinet by 85.4.

2.Minimally configured system contains one regulator, one CPU module, one memory

module, one IOP module, and one Ethernet controller.

3.Power cord is required for system cabinet and each I/O expansion cabinet.
4.Receptacle type is Hubbell 516R6 or equivalent.

Содержание VAX 7000

Страница 1: ...availability in the event of a power regulator failure Systems can be configured with up to three power regulators Optional system level Uninterruptable Power Supplies UPS are available to support CPU...

Страница 2: ...software product warranty Order Number Memory 7MAME KA KB KC 512 MB one 512 MB module 7MAMH KA KB KC 2 GB one 2 GB module Note xA 60 Hz 208 V xB 50 Hz 380 416 V xC 50 60 Hz Japan Step 1a CPU Symmetric...

Страница 3: ...ystem when multiple systems are used in an OpenVMS Cluster environment BNCIA xx Computer interconnect cable sets Connect Star Coupler to system and SW800 or HSCxx Choose required length 10 20 or 45 m...

Страница 4: ...imum included One maximum One maximum One each Two each Two Two The I O expansion cabinet includes one power regulator and provides space for two additional power regulators and six expansion bays two...

Страница 5: ...net controller included with each system Select additional devices if required Note Connection of system to Ethernet requires an Ethernet transceiver cable See the Network Products Guide for details L...

Страница 6: ...equired Step 9 Software Note An OpenVMS Group Table Patch is available that enables OpenVMS Concurrent Use License PAKs and Distributed Interactive User License PAKs it can be duplicated and used with...

Страница 7: ...Distributed Interactive 32 User License QL 09SA9 BH OpenVMS VAX Distributed Interactive 64 User License QL 09SAA BR OpenVMS VAX Distributed Interactive 128 User License QL 09SAB BR OpenVMS VAX Distrib...

Страница 8: ...DEMNA M XMI Ethernet controller 3 3 DWLMA AA XMI plug in unit 4 DWLMA BA XMI plug in unit 4 KFMSA BA XMI DSSI adapter 3 3 DMB32 M VAXBI multifunction controller 3 3 DWMBB LA VAXBI plug in unit 4 4 RZ...

Страница 9: ...000 Btu hr 13 800 W Power requirements3 U S Canada Europe APA Japan Nominal voltage Frequency range Phases Maximum input current phase Surge current Rating Power cap system Receptacle site Receptacle...