Compaq VAX 7000 Скачать руководство пользователя страница 6

VAX 7000 Model 810

4.36   VAX  Systems

 

Step 6—OpenVMS Cluster Options

 

For OpenVMS Cluster configurations, select appropriate OpenVMS Cluster options. CI controller, BNCIA cables, and
VAXcluster Software license required.

 

HSJ50-AF/AH/AJ

 

StorageWorks array controller, supports up to 36 SCSI-2 devices. Includes 32/64/128 MB Read
Cache and controller based disk striping.

 

HSD10-BF

 

StorageWorks array controller; supports up to seven SCSI-2 devices.

 

HSD30-CD/CF

 

StorageWorks array controller;  supports up to 18 SCSI-2 devices.

 

SW5xx/SW8xx

 

StorageWorks arrays. See Storage Devices for details.

 

BNCIA-xx

 

Computer interconnect cable sets—connects Star Coupler to system and SW800 or HSCxx Choose
required length of 10, 20 or 45 m (10 m = 32.8 ft, 20 m = 65.6 ft, 45 m = 147.6 ft).

 

SC008-AC

 

8-port Star Coupler; maximum five Star Couplers per system.

 

SC008-AD

 

Star Coupler; Upgrades SC008-AC to 16 ports; maximum one per SC008-AC.

 

QL-VBRA5-AA

 

VAXcluster license; required with each system that will connect to an OpenVMS Cluster.

 

Step 7—Console Terminal

 

A console terminal with EIA-232 25-pin D-subminiature connector and printer required unless otherwise available.

 

VT510-xx

 

VT510 terminal

 

LA75S-xx

 

LA75 Plus printer

 

LAXXS-AD

 

VT510/LA75 table for both VT510 and LA75

 

Step 8—Terminals and Printers

 

Order printers and terminals if required.

 

Step 9—Software

 

Note: An OpenVMS Group Table Patch is available that enables OpenVMS Concurrent Use License PAKs and

Distributed Interactive User License PAKs; it can be duplicated and used with each valid license.  Customers are
allowed to install and use the patch under their existing license agreement.  The kit is available on the Internet at the
following address: http://www.service.digital.com/html/patch_service.html.  It can also be obtained by ordering the
following:

 

QA-MT3AC-H8

 

OpenVMS VAX and Alpha Group Table Patch on CD-ROM

OpenVMS VAX Concurrent Use Licenses

 

OpenVMS VAX Concurrent Use licenses are for customers running OpenVMS VAX V6.2 or greater, see above note.

 

OpenVMS VAX Concurrent Use license provides the right to interactively use the operating system by the specified
number of concurrent users on a designated OpenVMS system.  OpenVMS Concurrent Use licenses can be moved from
one OpenVMS system to another OpenVMS system at user discretion and can be shared in a mixed OpenVMS VAX and
OpenVMS Alpha Cluster.

 

QL-MT3AA-3B

 

OpenVMS Concurrent Use 1-user license

 

QL-MT3AA-3C

 

OpenVMS Concurrent Use 2-user license

 

QL-MT3AA-3D

 

OpenVMS Concurrent Use 4-user license

 

QL-MT3AA-3E

 

OpenVMS Concurrent Use 8-user license

 

QL-MT3AA-3F

 

OpenVMS Concurrent Use 16-user license

 

QL-MT3AA-3G

 

OpenVMS Concurrent Use 32-user license

 

QL-MT3AA-3H

 

OpenVMS Concurrent Use 64-user license

 

QL-MT3AA-3J

 

OpenVMS Concurrent Use 128-user license

 

QL-MT3AA-3K

 

OpenVMS Concurrent Use 256-user license

Содержание VAX 7000

Страница 1: ...availability in the event of a power regulator failure Systems can be configured with up to three power regulators Optional system level Uninterruptable Power Supplies UPS are available to support CPU...

Страница 2: ...software product warranty Order Number Memory 7MAME KA KB KC 512 MB one 512 MB module 7MAMH KA KB KC 2 GB one 2 GB module Note xA 60 Hz 208 V xB 50 Hz 380 416 V xC 50 60 Hz Japan Step 1a CPU Symmetric...

Страница 3: ...ystem when multiple systems are used in an OpenVMS Cluster environment BNCIA xx Computer interconnect cable sets Connect Star Coupler to system and SW800 or HSCxx Choose required length 10 20 or 45 m...

Страница 4: ...imum included One maximum One maximum One each Two each Two Two The I O expansion cabinet includes one power regulator and provides space for two additional power regulators and six expansion bays two...

Страница 5: ...net controller included with each system Select additional devices if required Note Connection of system to Ethernet requires an Ethernet transceiver cable See the Network Products Guide for details L...

Страница 6: ...equired Step 9 Software Note An OpenVMS Group Table Patch is available that enables OpenVMS Concurrent Use License PAKs and Distributed Interactive User License PAKs it can be duplicated and used with...

Страница 7: ...Distributed Interactive 32 User License QL 09SA9 BH OpenVMS VAX Distributed Interactive 64 User License QL 09SAA BR OpenVMS VAX Distributed Interactive 128 User License QL 09SAB BR OpenVMS VAX Distrib...

Страница 8: ...DEMNA M XMI Ethernet controller 3 3 DWLMA AA XMI plug in unit 4 DWLMA BA XMI plug in unit 4 KFMSA BA XMI DSSI adapter 3 3 DMB32 M VAXBI multifunction controller 3 3 DWMBB LA VAXBI plug in unit 4 4 RZ...

Страница 9: ...000 Btu hr 13 800 W Power requirements3 U S Canada Europe APA Japan Nominal voltage Frequency range Phases Maximum input current phase Surge current Rating Power cap system Receptacle site Receptacle...