o Bays 0, 1, 2, and 3 are recommended for hard drives configured as an
array.
o A maximum of seven SCSI-2 devices may be added.
o The SCSI ID for each device should be the same as the bay number
(Bay 0 = SCSI ID 0).
Mass Storage Devices in the Removable Media Area
To remove a mass storage device in the Removable Media Area:
1. Remove the Side Access Door.
2. Swing the Air Baffle open.
3. Remove power and signal cables.
4. Remove the retaining screws (2).
5. Slide the storage device out of the drive bay.
6. Secure with retaining screws (2).
7. Reverse steps for installation.
8. Replace Side Access door.
9. Run the EISA Configuration Utility if replaced drive is a different size
than the drive it is replacing.