Compaq.com - Compaq Presario Maintenance and Service Guide - 5200 Series
United States December 10, 2002
Maintenance and Service Guide
Compaq Presario 5000, 5100, and 5200 Series Computers
MSG index
Diagnostic error
codes
Troubleshooting
without
diagnostics
l
TROUBLESHOOTING
Diagnostic Error Codes (continued)
Hard drive error codes
Error
Code
Description
Recommended Action
1700-
xx
Hard drive ID types test failed
The following steps apply to error codes 1700-
xx through 1799-xx:
1 Run
2
Replace the hard drive signal and power
cables
3
and retest.
4 Replace the
1701-
xx
Hard drive format test failed
1702-
xx
Hard drive read test failed
1703-
xx
Hard drive write/read/compare
test failed
1704-
xx
Hard drive random seek test
failed
1705-
xx
Hard drive controller test failed
1706-
xx
Hard drive ready test failed
1707-
xx
Hard drive recalibration test
failed
1708-
xx
Hard drive format bad track
test failed
1709-
xx
Hard drive reset controller test
failed
1710-
xx
Hard drive park head test failed
1714-
xx
Hard drive file write test failed
1715-
xx
Hard drive head select test
failed
1716-
xx
Hard drive conditional format
test failed
1717-
xx
Hard drive ECC* test failed
1719-
xx
Hard drive power mode test
failed
1719-x
Hard drive power mode test
failed
1730-x
Fixed Disk 0 does not support
DMA Mode
1731-x
Fixed Disk 1 does not support
DMA Mode
1740-x
Fixed Disk 0 failed Set Block
Mode command
1741-x
Fixed Disk 1 failed Set Block
Mode command
1750-x
Fixed Disk 0 failed Identify
command
1751-x
Fixed Disk 1 failed Identify
command
1760-x
Fixed Disk 0 does not support
Block Mode
1761-x
Fixed Disk 1 does not support
Block Mode
1790-x
Disk 0 Configuration Error
1792-x
Secondary Disk Controller
Failure
1799-
xx
Invalid hard drive type failed
*Error Correction Code
Tape drive error codes
Error
Code
Description
Recommended Action
1900-
xx
Tape ID failed
The following steps apply to error codes 1900-xx
through 1906-xx:
1 Replace the tape cartridge and retest.
2 Check and/or replace the signal cable and
retest.
3 Replace the tape drive and retest.
4 Replace the
and retest.
1901-
xx
Tape servo write failed
1902-
xx
Tape format failed
1903-
xx
Tape drive sensor test
failed
1904-
xx
Tape BOT/EOT test
failed
1905-
xx
Tape read test failed
1906-
xx
Tape
write/read/compare
failed
SuperDisk error codes (available on select models)
Error
Code
Description
Recommended Action
xxx-101
Drive Not Ready The following steps apply to all error codes except 656-
101 and 656-032:
1 Replace the diskette and retest.*
2
Check and/or replace the power and signal
cables
and retest.
3
and retest.
4 Replace the
xxx-032
Incorrect Media
Present
xxx-001
xxx-051
Verify Error
xxx-002
xxx-052
Seek Error
xxx-003
xxx-053
Read Error
xxx-004
xxx-054
Write Error
xxx-006
Data Compare
Error
xxx-008
Write Protect
Failure
xxx-011
LED Error
xxx-021
Format Error
xxx-022
SuperDisk
format pattern
not found
* Boot to DOS (Command Prompt only) or Windows (Not Safe Mode). Press
the SuperDisk drive eject button (located on the front bezel) to eject the
diskette and retest.
Pointing device interface error codes
Error
Code
Description
Recommended Action
8601-
xx
Pointing Device Interface
test failed
1. Replace with a working pointing device and retest.
and retest.
Audio error codes
Error
Code
Description
Recommended Action
3206-
xx
Audio System Internal
Error
Replace the
CD or DVD error codes
Error
Code
Description
Recommended Action
3301-xx
3305-xx
66XX-xx
CD or DVD
drive read test
failed
The following steps apply to error codes 3301-xx
through 3305-xx and 66XX-xx:
1 Replace the CD or DVD disk and retest.*
2 Check the jumper settings on the
drive.
3
Check and/or replace the power and signal
cables
4
5 Replace the backplane.
* Boot to DOS (Command Prompt only) or Windows (Not Safe Mode). Press
the CD or DVD drive eject button (located on the front bezel) to eject the CD or
DVD and retest.
privacy statement
legal notices
http://h18000.www1.hp.com/athome/support/msgs/5000/diags2.html [12/10/2002 9:29:28 AM]