background image

1-22

   English

Writer: Marianne Silvetti    Saved by: Marianne Silvetti    Saved date: 03/03/98 2:30 PM

Pages: 26    Words: 3913    Template: c:\msoffice\templates\normal.dot

File Name Ch1appa.doc    Part Number 284986-002

S

PECIFICATIONS

Compaq P110 Color Monitor

Display

21-in aperture grille CRT

53.3 cm

Viewable Image Size

19.8-in diagonal

50.2 cm

Face Treatment

Antiglare/antireflective/antistatic coatings

Weight (Unpacked)

 70 lb

 32 kg

Maximum Dimensions

   Height

 20.6 in

52.4 cm

   Depth

 19.8 in

50.2 cm

   Width

 20.1  in

51.1 cm

Maximum Graphics
Resolution

 1600 X 1200 at 85 Hz Refresh Rate

Text Mode

 720 X 400

Aperture Grille Pitch

 0.25 mm (center)

Horizontal Frequency

 31 to 107 kHz

Vertical Frequency

 60 to 160 Hz

Environmental
Requirements Temperature

   Operating Temperature
   Storage Temperature

 50 to 95

°

F

-22 to 140

°

F

  10 to 35

°

C

-30 to 60

°

C

Humidity (Non-Condensing)

  Operating
  Non-Operating

 

20 to 80%

  5 to 90%

Power Source

100 - 240 VAC, 50 - 60 Hz

Power Consumption

< 160 watts

USB Connectors

1 upstream port to connect hub to the computer

4 downstream ports to connect up to 4 USB peripherals

Input Terminal

15-pin D-type connector with cable

5 BNC connectors (cable not included)

Содержание P 110

Страница 1: ... of this guide may be photocopied or reproduced in any form without prior written consent from Compaq Computer Corporation 1997 Compaq Computer Corporation All rights reserved Printed in Singapore Compaq Deskpro QVision Registered U S Patent and Trademark Office The software described in this guide is furnished under a license agreement or nondisclosure agreement The software may be used or copied...

Страница 2: ...ion The Compaq P110 Color Monitor is a high resolution large screen monitor intended for use with high end graphics controller boards from Compaq The large screen is recommended for advanced graphics user interfaces GUIs high performance graphics and digital video applications such as computer aided design computer aided engineering desktop publishing document image processing and Windows 95 and W...

Страница 3: ...en in five different languages English Dutch French German and Spanish Universal Serial Bus Hub interface four Plug and Play connectors for use with USB peripherals mouse etc Plug and Play capability if supported by your system Fault Management and Asset Control Multisync with screen expansion Twenty one preset display resolutions including 1600 1200 85 Hz Energy Saver feature Macintosh compatible...

Страница 4: ...mputer system and other attached devices then follow these steps 1 Place the monitor in a convenient well ventilated location near but not on top of your computer WARNING This monitor weighs approximately 70 pounds and is not intended to be placed on top of a computer Place the monitor directly on a desktop or other work surface To reduce the risk of possible injury do not attempt to lift the moni...

Страница 5: ...onnect the monitor power cord 3 to the rear panel of the monitor then plug the other end into an electrical outlet 4 that is easily accessible and close to the monitor WARNING To reduce the risk of electric shock or damage to your equipment do not disable the power cord grounding feature This equipment is designed to be connected to a grounded earthed power outlet that is easily accessible to the ...

Страница 6: ...ard mouse or video camera USB connector 2 is used to connect the USB signal cable to the computer The USB signal cable is included with the monitor Using BNC Connectors A signal cable with BNC connectors may be used in place of the 15 pin signal cable To connect two computers to the monitor a BNC connector may be used together with the 15 pin signal cable If you have separately purchased a signal ...

Страница 7: ...place The color of the wires may vary so refer to the manufacturer s instructions included with the BNC connectors Usually the connectors are color coded from left to right in the following order 1 Red R for the red video connector 2 Green G for the green video connector 3 Blue B for the blue video connector 4 White for horizontal sync H 5 Black for vertical sync V CAUTION When using a signal cabl...

Страница 8: ...llustrated WARNING To reduce the risk of electric shock or damage to your equipment do not disable the power cord grounding feature This equipment is designed to be connected to a grounded earthed power outlet that is easily accessible to the operator The grounding plug is an important safety feature CAUTION Be sure that the power outlet you plug your power cord into is easily accessible and locat...

Страница 9: ...ss to an appropriate level This function is turned On and Off using the on screen display 2 Contrast Dial Adjusts Contrast 3 Brightness Dial Adjusts Brightness 4 Select Button 1 Launches on screen display 2 Selects function adjustments 3 Exits menus and on screen display 5 Minus Button Selects or adjusts the functions 6 Plus Button Selects or adjusts the functions 7 Power Switch Turns the monitor ...

Страница 10: ...en color balance beam landing and convergence Moire Minimizes interference patterns that occasionally appear on the screen Degauss Corrects image distortion or color impurity caused by external magnetic fields Input DSub BNC Select when using a 15 pin signal cable and BNC connectors together If you are using only one of these cables connectors this function automatically adjusts Language Lists fiv...

Страница 11: ...ng the Minus button 2 located on the monitor front panel To reverse or back up press the Plus button 3 3 Highlight your choice and press the Select button 1 again For example to select the Position menu press the Minus button 2 until Size and Position is highlighted then press the Select button 1 to choose it Monitor with On Screen Display 4 A second level menu displays with expanded menu items Ag...

Страница 12: ...Name Ch1appa doc Part Number 284986 002 6 Adjust the third level menu displays in the same manner 7 To exit from the on screen menu select Exit from the Main Menu If the display is a second or third level menu select Save and Return or Cancel then select Exit from the Main Menu The on screen display is easy to use just follow the instructions on the screen ...

Страница 13: ... 350 at 31 5 kHz 70 Hz 2 VESA 640 350 at 37 9 kHz 85 Hz 3 Industry Standard 640 480 at 31 5 kHz 60 Hz 4 VESA 640 480 at 37 5 kHz 75 Hz 5 VESA 640 480 at 43 3 kHz 85 Hz 6 Industry Standard 720 400 at 31 5 kHz 70 Hz 7 VESA 720 400 at 37 9 kHz 85 Hz 8 VESA 800 600 at 37 8 kHz 60 Hz 9 VESA 800 600 at 46 9 kHz 75 Hz 10 VESA 800 600 at 53 7 kHz 85 Hz 11 Macintosh Compatible 832 624 at 49 7 kHz 75 Hz 12 ...

Страница 14: ...just the parameters of the monitor screen by using the on screen display User changes can be made to any or all of these modes and saved in memory The monitor automatically stores the new setting then automatically recognizes the new mode just as it does a preset mode In addition to the 21 preset modes that can be changed and stored there are 15 user modes that can be entered and stored To revert ...

Страница 15: ...vels Mode Power Usage Description Full Power Less than 160 watts ON Normal operation Power LED is green Suspend Less than 15 watts Monitor screen is blanked Power LED turns yellow Full power mode returns quickly Sleep Less than 8 watts Monitor screen is blanked Power LED turns amber There is a brief warm up period before returning to full power mode The energy saver levels listed are for the monit...

Страница 16: ... the outlet does not exceed the current rating of the electrical outlet and the total ampere rating of the products connected to the cord does not exceed the rating of the cord Install the monitor near an outlet that you can easily reach Disconnect the product by grasping the plug firmly and pulling it from the outlet Never disconnect it by pulling the cord Unplug the monitor from the wall outlet ...

Страница 17: ...t are covered by the operating instructions If the monitor is not operating properly or has been dropped or damaged contact your Compaq authorized dealer reseller or service provider Cleaning the Monitor To clean the monitor follow these steps 1 Turn off the monitor and the computer 2 Dust the monitor by wiping the screen and the cabinet with a soft clean cloth If the screen requires additional cl...

Страница 18: ...r lowest settings 2 Increase brightness until the background portions of the screen are visible then slowly reduce brightness until the background is just extinguished 3 Adjust contrast control to your preference Optimizing Focus The default image size is preset at the factory The Size and Position controls in the on screen display can be used to increase the screen size beyond the default setting...

Страница 19: ...1 18 English Writer Marianne Silvetti Saved by Marianne Silvetti Saved date 03 03 98 2 30 PM Pages 26 Words 3913 Template c msoffice templates normal dot File Name Ch1appa doc Part Number 284986 002 ...

Страница 20: ...e will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connec...

Страница 21: ... tested with the Compaq 630 Series monitors were evaluated and found compliant to the requirements of ZH 1 618 German Safety Regulations for Display Work Places in the Office Sector in the Text Mode 720 400 using MS DOS Version 3 31 or higher and BASICA as published by Compaq Computer Corporation EPA Energy Star Compliance Monitors that are marked with the Energy Star Logo meet the requirements of...

Страница 22: ...e CE Marking comply with both the EMC Directive 89 336 EEC and the Low Voltage Directive 73 23 EEC issued by the Commission of the European Community Compliance with these directives implies conformity to the following European norms EN55022 CISPR 22 Radio Frequency Interference EN50082 1 IEC801 2 IEC801 3 IEC801 4 Electromagnetic Immunity EN61000 3 2 Harmonic Distortion Compliance EN60950 IEC950 ...

Страница 23: ... 50 2 cm Width 20 1 in 51 1 cm Maximum Graphics Resolution 1600 X 1200 at 85 Hz Refresh Rate Text Mode 720 X 400 Aperture Grille Pitch 0 25 mm center Horizontal Frequency 31 to 107 kHz Vertical Frequency 60 to 160 Hz Environmental Requirements Temperature Operating Temperature Storage Temperature 50 to 95 F 22 to 140 F 10 to 35 C 30 to 60 C Humidity Non Condensing Operating Non Operating 20 to 80 ...

Страница 24: ...r Use the following signal transmission schemes when BNC connectors are connected to the monitor Separate TTL Syncs Separate Videos Connect all five Red Green Blue Black and White of the interface connections Composite Sync Separate Analog Videos Connect the Red Green and Blue video inputs and the horizontal sync input Sync Signal Definition Horizontal and vertical sync signals are both provided t...

Страница 25: ...for use in the country where you purchased the equipment Power cord sets must meet the requirements of the country where you use the monitor For more information on power cord set requirements contact your Compaq authorized dealer reseller or service provider General Requirements The requirements listed below are applicable to all countries 1 The length of the power cord set must be at least 5 00 ...

Страница 26: ...KO 1 France UTE 1 Germany VDE 1 Italy IMQ 1 Japan JIS 3 The Netherlands KEMA 1 Norway NEMKO 1 Sweden SEMKO 1 Switzerland SEV 1 United Kingdom BSI 1 United States UL 2 Notes 1 The flexible cord must be HAR Type HO5VV F 3 conductor 0 75 mm2 conductor size Power cord set fittings appliance coupler and wall plug must bear the certification mark of the agency responsible for evaluation in the country w...

Страница 27: ...e Ch1appa doc Part Number 284986 002 The appliance coupler flexible cord and wall plug must bear a T mark and registration number in accordance with the Japanese Dentori Law The flexible cord must be Type VCT or VCTF 3 conductor 0 75mm2 conductor size The wall plug must be a two pole grounding type with a Japanese Industrial Standard C8303 15A 125V configuration ...

Отзывы: