1210 - 08
Modem timed out waiting
for remote response
1210 - 09
Modem exceeded
maximum redial limit
1210 - 10
Line quality prevented
remote connection
1210 - 11
Modem timed out waiting
for remote connection
1210 - 17
Tone detection failure
=============================================================================
Table 3-10.
Fixed Disk Drive Test Error Codes
=============================================================================
Error
Recommended
Code
Description
Action
-----------------------------------------------------------------------------
1700 - xx
Fixed disk ID drive
The following steps apply
types test failed
to error codes 1700 - xx
through 1719 - xx:
1701 - xx
Fixed disk drive format
1.
Replace the fixed disk
test failed
drive and retest.
2.
Replace the power
1702 - xx
Fixed disk drive read
distribution
test failed
board and retest.
3.
Replace the I/O board
1703 - xx
Fixed disk drive write
and retest.
read compare test failed
1704 - xx
Fixed disk drive random
seek test failed
1705 - xx
Fixed disk drive
controller test failed
1706 - xx
Fixed disk drive ready
test failed
1707 - xx
Fixed disk drive recalibrate
test failed
1708 - xx
Fixed disk drive format bad
track test failed
1709 - xx
Fixed disk drive reset
controller test failed
1710 - xx
Fixed disk drive park head
test failed
-----------------------------------------------------------------------------
Error
Recommended
Code
Description
Action
-----------------------------------------------------------------------------
1714 - xx
Fixed disk drive file
The following steps apply
write test failed
to error codes 1700 - xx
through 1719 - xx:
1715 - xx
Fixed disk drive head
1.
Replace the fixed disk
Содержание Compaq 486