
QuickSpecs
ProLiant
BL20p and p-Class system
DA-11411 World Wide — Version
4
— September 19, 2002
21
Technical Specifications
Dimensions
Height
10.405 in/26.43 cm
Width
1.535 in/3.899 cm
Operating and Performance
Specifications for Interconnect
GbE Switch
Depth
27.697 in/70.35 cm
Weight
11.5 lb/5.2 kg per interconnect switch
Performance
3.2 Gbps Switching bandwidth per server enclosure
4.4 Gbps uplink bandwidth per server enclosure
9.6 Million pps aggregate throughput per server enclosure (64-byte packets)
Full-wire speed for all connections
Auto-negotiation and auto-sensing with full-duplex support
Forwarding mode
Store and forward
MAC Addresses
8,191 per interconnect switch; MAC address based filtering and MAC address
packet priority configuring
Forwarding table age time
Maximum age: 10 to 9999 seconds; default: 3000 seconds
Memory
32MB Main, 6MB flash and 16MB packet buffer per interconnect switch
Compliance
IEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.1D, 802.1p, 802.3ac, 802.3ad
(Static), 802.1Q, and 802.3x
SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9
MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface MIB (RFC 2233),
801.1Q MIB (RFC 2684), RMON1 MIB (RFC 1757) groups 1, 2, 3, and 9, and
Ethernet MIB (RFC1643)
Network transfer rate
10 Base-T (half-duplex)
10 Mbps
10 Base-T (full-duplex)
20 Mbps
100 Base-TX (half-duplex)
100 Mbps
100 Base-TX (full-duplex)
200 Mbps
1000 Base-TX (half-duplex)
1000 Mbps
1000 Base-TX (full-duplex)
2000 Mbps
1000 Base-SX (full-duplex)
2000 Mbps
Connector
RJ-45, DB-9 (C-GbE Interconnect Kit)
LC fiber, RJ-45, DB-9 (F-GbE Interconnect Kit)
EMI
FCC Class A
ICES-003 Class A
AS/NZS 3548 Class A
VCCI Class A
Safety
UL/CUL Listed Accessory
Power requirements
48V: 1050 mA, 50 W maximum (per interconnect switch)
Temperature range
Operating
50° to 95° F/10° to 35° C
Non-operating
-22° to 140° F/-30° to 60° C
Operating
20% to 80%
Relative humidity
(non-condensing)
Non-operating
5% to 95%
Operating
82.4° F/28° C
Wet bulb temperature
Non-operating
101.7° F/38.7° C
Note: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper
operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/ 9,144 m or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of
113° F/45° C. Altitude maximum for storage is 70 KPa.