![Compaq AP400 - Professional - 64 MB RAM Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/compaq/ap400-professional-64-mb-ram/ap400-professional-64-mb-ram_troubleshooting-manual_2645533063.webp)
B-2
POST Error Messages - Numbered
POST Error Messages
Continued
Screen Message
Beeps*
Probable Cause
Recommended Action
163-Time & Date Not Set
2S
Invalid time or date in
configuration memory.
RTC (real-time clock)
battery may need to be
replaced. Battery life is
approximately 3 years.
CMOS jumper may not
be properly installed.
Set the date and time under Control
Panel.
If the problem persists, replace the
RTC battery.
Check for proper placement of the
CMOS jumper.
164-Memory Size Error
2S
Memory configuration
is incorrect.
1. Run Computer Setup (F10
Setup) or Windows utilities.
2. Make sure memory module(s)
(if any) are installed properly.
3. Verify proper memory module
type.
4. If third-party memory has been
added, test using Compaq-only
memory.
183-Invalid Processor
Jumper Setting
2S
System board jumper
improperly set.
Reset system board jumpers to
match processor and bus speeds.
201-Memory Error
None
RAM failure.
1. Run computer Setup (F10
Setup) or Windows utilities.
2. Ensure memory and continuity
modules are installed correctly.
3. Verify proper memory module
type.
4. Remove and replace memory
module(s) one at a time to
isolate faulty module.
5. Replace the faulty memory
module(s).
6. If error persists after replacing
memory modules, replace the
system board.
202-Memory Type Mismatch None
Memory modules do not
match each other.
Replace memory modules with
matched sets.
207-ECC Corrected Single
Bit Errors in DIMM/SIMM
Pair(s) X,X,... in Memory
Socket(s) y,y
2S
Single Bit ECC error.
1. Verify proper memory module
type.
2. Try another memory socket.
3. Replace memory module if
problem persists.
* L = Long, S = Short