4-16
Using Integrated Remote Console
Writer: Caroline Juszczak Project: Compaq Integrated Remote Console User Guide Comments: 281862-00x
File Name: E-CH04.DOC Last Saved On: 12/21/98 10:32 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
If you are using Insight Manager as the terminal application, as shown in Figure
4-11, the reconnection is reestablished without user intervention. The Insight
Manager terminal window is placed into “Callback mode”, indicated by the
phrase “Waiting for Callback…” located in the status window. When power
returns to the server, Remote Console uses the supplied phone number to
attempt to reestablish a connection. Insight Manager answers the incoming call
and redisplays the Main Menu.
If you are using a standard ANSI terminal emulation application, like Windows
HyperTerminal, the method for putting the modem in auto-answer mode varies.
Some applications, like HyperTerminal, do not provide for answering incoming
calls. The modem can be manually placed in auto-answer mode by entering the
modem auto answer string (usually “ATS0=1”) followed by Enter. The modem
responds by displaying “OK” in the terminal window. The modem answers the
incoming call from Remote Console.
NOTE
: Insight Manager is the recommended management application if this
functionality is desired.
Figure 4-12. Power Cycle using ANSI terminal emulation emulation