POST Error Messages
Compaq Smart Array 5300 Controller User Guide
G-9
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: q-appg POST messages.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 7/22/02 10:54 AM
Table G-1: POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1786
Slot x Drive Array Recovery Needed.
The following SCSI drive(s) need
Automatic Data Recovery: SCSI port
(
y
): SCSI ID (
x
)
Select
F1
to continue with recovery of
data to drive(s)
.
Select
F2
to continue
without recovery of data to drive(s)
.
-or-
Slot x drive array recovery needed.
Automatic Data Recovery previously
aborted! The following SCSI drive(s)
need Automatic Data Recovery
(rebuild):
SCSI port (
y
): SCSI ID (
x
)
Select
F1
to retry Automatic Data
Recovery to drive
.
Select
F2
to
continue without starting Automatic
Data Recovery.
The message normally appears when a
drive is replaced in a fault-tolerant
configuration when the system is powered
down. In this case, press the
F1
key to start
the automatic data recovery process.
A 1786 POST message will appear if the
previous rebuild attempt was aborted for
any reason. Run the Array Diagnostics
Utility (ADU) for more information. If the
replacement drive was failed, try using
another replacement drive. If rebuild was
aborted due to a read error from another
physical drive in the array:
1.
Back up all readable data on the array.
2.
Run Diagnostics Surface Analysis.
3.
Restore your data.
1787
Slot x drive array operating in Interim
Recovery Mode. The following SCSI
drive(s) should be replaced:
SCSI port (y): SCSI ID (x)
Following a system restart, this message
reminds you that drive
x
is defective and
fault tolerance is being used. Replace drive
x
as soon as possible. A loose or defective
cable may also cause this error.
continued