Compaq 158222-B21 - StorageWorks Fibre Channel SAN Switch 8 Скачать руководство пользователя страница 4

Page 4

Metric Racks

1. Position each mounting bracket (see Figure 7,

1

) with the 

rail holes pencil-marked M.

2. Identify clip nut

2

 mounting holes and install two clip nuts 

for each mounting bracket.

3. Secure each mounting bracket, using pan head SEMS 

screws (10-32 x 5/8 inches).

Attaching the Slide Brackets

Secure two slide brackets to each switch.

CAUTION:  

Ensure that the mounting screws are the proper length 

and that flat washers are used. Installing screws longer than 9/32 
inch or without a flat washer may damage the switch.

For older 8-port switches (380591–B21/ DS–DSGGA–AA) 
in rack-front and rear installations, see Figure 8.

Use four pan head SEMS screws (10-32 x 9/32 inches) and 
four flat washers to attach the mounting brackets to the 
switch.

IMPORTANT:  

Attach the slide brackets using a flat washer with each 

screw. Without the flat washers, the screws contact with the power 
supply assembly inside the switch chassis.

For newer 8-port switches 
(176219–B21/DS–DSGGC–AA), see Figures 9 and 10.

Use four pan head SEMS screws (8-32 x 1/4 inches) and 
four flat washers to attach the mounting brackets to the 
switch.

IMPORTANT:  

Attach the slide brackets using a flat washer with each 

screw. Without the flat washers, the screws may contact components 
inside the switch chassis.

NOTE:  

Install this 8-port switch with the cables at either the front or the 

rear of the rack.

— For cable-front installations, attach the brackets as 

shown in Figure 9.

— For cable-rear installations, attach the brackets as 

shown in Figure 10.

2

1

1

CXO6840B

2

7

CXO7468B 

8

CXO7503B

9

CXO7504B

10

Содержание 158222-B21 - StorageWorks Fibre Channel SAN Switch 8

Страница 1: ...Channel Switch 8 16 Port Universal Mounting Kit Third Edition November 2001 Part Number EK GGAAB IA C01 Compaq Computer Corporation About This Card This card identifies the contents of the universal m...

Страница 2: ...k rail holes as required using a mounting bracket IMPORTANT Ensure that the template front and back are used according to the desired installation orientation In rack front installations the template...

Страница 3: ...rallel in the rack from front to back 2 Install a clip nut 2 and secure using pan head SEMS screws 10 32 x 5 8 inches RETMA 42U and Compaq Classic Racks 1 Connect an extender bracket to each mounting...

Страница 4: ...nd four flat washers to attach the mounting brackets to the switch IMPORTANT Attach the slide brackets using a flat washer with each screw Without the flat washers the screws contact with the power su...

Страница 5: ...lled in pairs using a second universal mounting kit to occupy a 3U space in the rack References to upper and lower location the top 1 5U or bottom 1 5U are used to indicate the placement of the switch...

Страница 6: ...witch parallel to the floor while sliding the slide brackets into the mounting brackets Tilting the switch up or down may result in damage to the brackets IMPORTANT All switches use the same cable rou...

Страница 7: ...here to illustrate this process Install a snap on cable tie into each slide bracket as shown in Figure 19 representative example as desired and route the power cables downward along the rack vertical...

Отзывы: