Error Messages
6-9
Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq StorageWorks SAN Switch 16 Installation and Hardware Guide Comments:
Part Number: EK-BCP28-IA / 161356-001 File Name: G-CH6 ERROR MESSAGES.DOC Last Saved On: 9/30/99 11:32 AM
Error Message Table
Table 6-3 defines each error name and describes the actions necessary to
correct each error.
Table 6-3
Diagnostic Error Messages
Message
Description
Probable Cause
Action
DIAG-BADINT
Err#1030, 2030
[centralMemoryTest,
cmiTest]
The port received an interrupt
when it was not expecting one.
ASIC failure
Replace motherboard
assembly
DIAG-BUS_TIMEOUT
Err#0B0F, 4040F
[portRegTest,
sramRetentionTest]
An ASIC register or ASIC SRAM
did not respond to an ASIC data
access.
ASIC failure
Replace motherboard
assembly
DIAG-CAMINIT
Err#223B
[camTest]
The port failed to initialize due to
one of the following reasons:
■
Switch not disabled
■
Diagnostic queue absent
■
Malloc failed
■
Chip is not present
■
Port is not in loopback mode
■
Port is not active
Software
operational setup
error or
motherboard
failure
Retry, reboot or
replace motherboard
assembly
DIAG-CAMSID
Err#223C
[camTest]
An ASIC failed SID NO translation
test.
ASIC failure
Replace motherboard
assembly
DIAG-CLEAR_ERR
Err#0001
A port’s diag error flag (OK or
BAD) is cleared.
Informational
Only
None required
DIAG-CMBISRF
Err#1021
[centralMemoryTest]
An ASIC’s Central Memory
SRAMs did not complete the
BISR within the timeout period.
ASIC failure
Replace motherboard
assembly
continued