SAFETY INSTRUCTIONS
This appliance must only be used in an above ground open air
situation with natural ventilation, without stagnant areas, where gas
leakage is rapidly dispersed by wind and natural convection.
Any enclosure in which the appliance is used should comply with one
of the following:
(A) An enclosure with walls on all sides, but with no overhead cover.
(B) Within a partial enclosure that includes an overhead cover and no
more than two walls.
(C) Within a partial enclosure that includes an overhead cover and
more than two walls, the following must apply:
(1) At least 25% of the total wall area is completely open.
(2) 30% or more in total of the remaining wall side, back and front
wall areas is open and unrestricted.
(3) In the case of balconies, 20% or more of the total wall area must
remain open and unrestricted.