Chapter
2-24
CMD DATA
Description
return
41h
EC state notification
A0h
Return core code version number
One byte
A1h
Return platform id
‘COMPAL’
42h
Bank assign for EEPROM
None
0x00-0x07 Bank assign for EEPROM,work with 4D/4E command
replace 4B/4C command
None
43h
00h - FFh Get RAM value from EC, Host can use this command to
send address to get OEM RAM value. The address range
are from 00h to DFh.
1 WORD
0x19
Get PANEL ID
Panel id
44h
None
Get project ID
0x12
45h
Hook for every projects
NONE
46h
fan speed read
01h
fan speed 1
N = 60M/return value( rotate one circle 4 pulses)
N = 120M/return value( rotate one circle 2 pulses)
2 bytes
(high byte,
low byte)
02h
Fan speed 2
N = 60M/return value( rotate one circle 4 pulses)
N = 120M/return value( rotate one circle 2 pulses)
2 bytes
(high byte
low byte)
47h
Speaker mute On/Off
A7h Mute
off
None
A8h Mute
on
None
48h
Reserved for docking control
None
49h
Thermal control notification
A0h Fan
off
None
A1h
Fan speed level 1
None
A2h
Fan speed level 2
None
A3h HCT
enable
None
49h
A5h
Fan speed level 4
None
4Ah
Auto into S2R(Delay about 4 Secs) or S2D and resume by
timeout, This command provided engineer to verify S2R or
S2D and resume function is OK or not
Resume count(second base ), Range is from 0x02 to 0x7F
Bit7 = 0 -> Enabled S2R function
1 -> Enabled S2D function
0x02-0x7F Enabled S2R function
None
0x80-0xFF Enabled S2D function
None
Содержание ACY25 series
Страница 53: ...Chapter 3 Hardware Major Sub assembly Specification System interconnection For BY25 Chapter 3 1...
Страница 69: ...Chapter 4 AC DC CONVERTER ACY25 series Power System block diagram Chapter 4 1...
Страница 162: ...A 12...
Страница 166: ...A 16...
Страница 169: ...A 19...
Страница 171: ...A 21...
Страница 173: ...A 23...