ORIGINAL INSTRUCTIONS | Ref. quality process 002/03 | v. 01/09/2022 | K08021H09
17
8.
OPERATION
8.4.2
CONFIGURATION °C AND °F
After choosing between KG or LB:
1.
“°C °F ” will appear on the screen.
2.
Press “-” o “+” depending on whether you
want °C (Celsius degrees) or °F (Fahrenheit
degrees). You have 10 seconds to select.
Once the selection has been made, the
Cube will restart with the new configuration.
8.4.3
LOCKED KEYBOARD
To lock the digital display, simply press the
+ ( ) and - ( ) keys simultaneously for
3 seconds until the lock icon appears.
Fig. 5
To unlock the digital display just repeat the
same steps until the unlock icon appears.
Fig. 6
8.5.
CLEANING MODE
For a correct tamping consistency, daily
cleaning of the tamping disk is recommended.
To do this, press the CLEAN button.
The disk will lower to the pressing position
and stay there for 10 sec. During this time
you can clean it with a brush, or cloth
if the disc is wet.
Press the CLEAN button again to return
the disk to its idle position.
If you want the disk to remain in the
pressing position to allow more time for
the cleaning, switch off the appliance using
the switch (
9
)
3
2
NOTE: The grinder shouldn’t be
used in environments (SUCH AS
INDUSTRIAL KITCHENS) where
cleaning is done with direct water
spray cleaning.
Fig. 5
Fig. 6
° C F
o o