The Compac ComTank is a diesel fuel dispenser authorisation and reporting 
device designed to be flush-fitted to a wall, fuel tank or in the side of a shipping 
container. It is designed to be connected to Compac Master series pumps. 
ComTank specific Master series pumps with remote displays and nozzle 
holders are available to allow users to fully customise the location of 
authorisation panel, pump display, hose outlet and nozzle holder to suit their 
site requirements.  Features include: 

  Effective solution for tanks and pumps that need to be securely locked 

  Ideal for portable installations 

  Control interface for Master mechanical components 

  Remote mountable nozzle holders 

  Commercial or Retail display, with the option of remote mountable 

additional display 

  Single or Dual Hose 

  Choice of stainless steel panels (for corrosive situations) or gold 

passivated mild steel 

Authorisation Options 

  PIN pad 

  Electronic Tag (HID, iTrack or CWID - Compac Wireless Identifier- key 

tag or nozzle tag) 

  Swipe card 

Transaction Downloading Options 

  USB stick 

  CompacOnline 

Tank Gauging Options 

  Veeder-Root 

  Fafnir 

  Vega 

  Franklin 

 Options may vary depending on application. 

 These installation instructions refer specifically to the ComTank 

authorisation unit and related hardware. For detailed instructions on the 
installation, setup and calibration of pumps and for the operation of the 
authorisation and reporting systems, refer to their specific manual. 

 

 

Содержание ComTank

Страница 1: ...ComTank Unit Installation Sheet Version 1 0 0...

Страница 2: ...dustries Limited reserves the right to revise or change product specifications at any time This publication describes the state of the ComTank and related products at the time of publication and may n...

Страница 3: ...paration 9 Electrical Preparation 10 Precautions if Using Generator Power 10 Electrical Connection 11 Wiring Diagram Control Unit 12 Modem Connections 13 Powering up 14 Checking Pump Prices 14 Power o...

Страница 4: ...Information and Revision History Document Details ComTank Installation Sheet File Name and Location G Masters Installation Sheets ComTank Installation Sheet Current Revision Author s R Lacey Authorise...

Страница 5: ...installations Control interface for Master mechanical components Remote mountable nozzle holders Commercial or Retail display with the option of remote mountable additional display Single or Dual Hos...

Страница 6: ...that capacitors and back up batteries may power the unit even after mains power is removed Always turn off the power to the unit at the mains switch before removing or replacing software or memory IC...

Страница 7: ...ivers Power Tools Electric drill observe site safety protocols when using power tools Electrical Tools Wire cutters Wire stripper Crimping tool EPROM extractor Multimeter Earthing wrist strap Diagnost...

Страница 8: ...k has been installed correctly and is undamaged Report issues to site manager Inappropriate installation may void the warranty If uncertain contact your Compac agent for advice Site Preparation Refer...

Страница 9: ...to allow you to put the washers and nuts on the end of the 20mm long studs The plate the ComTank is mounted on should be rust protected if it is not made from stainless steel Ensure there is sufficien...

Страница 10: ...omponents within the cabinet When connecting to sites powered by generators please take the following precautions Install a power conditioner Although generators are fitted with power regulators most...

Страница 11: ...busbar at the bottom of the cabinet Pump Comms Connect the pump comms cable s to the terminals on the DIN rail If pumps do not communicate on start up swap the wires over Nozzle switches The nozzle sw...

Страница 12: ...Wiring Diagram Compac Industries Ltd Page 12 www compac co nz Wiring Diagram...

Страница 13: ...card to be fitted To fit the SIM card 1 Depress the small yellow button on the top of the cell modem 2 Remove the black plastic SIM card holder 3 Insert the SIM card 4 Refit the SIM card holder There...

Страница 14: ...ecific instructions for each option are either supplied or available from Compac The ComTank unit controls the pricing at the pumps In most circumstances the pricing information is sent to the unit ei...

Страница 15: ...ozzle Inserting the nozzle into the filler authorises the pump iTrack reader authorisation A unit attached to the vehicle authorises the pumps as it pulls into the forecourt All authorisation methods...

Страница 16: ...on on the receipts Finishing Up When you are confident the site is trading correctly complete the installation checklist If you do not have one a copy is attached at the end of these instructions Fax...

Страница 17: ...y from the prevailing wind and rain Check all panels are securely fastened using tamper proof fastenings where supplied Check that all cable entries to unit are through glands and unused glands are se...

Страница 18: ...that site administrators understand how to obtain transactions and administer cards Final Checks Yes No Ensure all cables are plugged back in after remote accessing Tidy up all rubbish and clean the...

Отзывы: