background image

INS_NWKSP2_REV–     07/10/14     PAGE 17

INSTALLATION AND OPERATION MANUAL 

NWKSP2

TECH SUPPORT: 1.888.678.9427

Agency Compliance

FCC

Changes or modifications not expressly approved by the party responsible for compliance 
could void the user’s authority to operate the equipment. This device complies with Part 15 of 
the FCC Rules. Operation is subject to the following two conditions:

• This device may not cause harmful interference, and

•  This device must accept any interference received, including interference that may cause 

undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital 
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference when the equipment is operated in a Industrial 
environment. This equipment generates, uses, and can radiate radio frequency energy 
and, if not installed and used in accordance with the instruction manual, may cause harmful 
interference to radio communications. Operations of this equipment in a residential area is likely 
to cause harmful interference in which case the user will be required to correct the interference 
at his own expense.

Industry Canada

This Class A digital apparatus complies with Canadian ICES-003. To reduce potential radio 
interference to other users, the antenna type and its gain should be so chosen that the 
equivalent isotropically radiated power (EIRP) is not more than that permitted for successful 
communication. This device complies with Industry Canada license-exempt RSS standard(s).

Operation is subject to the following two conditions:

•  This device may not cause interference, and

•   This device must accept any interference, including interference that may cause undesired 

operation of the device.

Cet appareil numérique de la classe A est confrome à la norme NMB-003 Canada. Pour réduire 
le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain doivent être 
choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui 
est nécessaire

pour une communication réussie. Cet appareil est conforme à la norme RSS Industrie Canada 
exempts de licence norme(s). Son fonctionnement est soumis aux deux conditions suivantes:

17 Compliance

•  Cet appareil ne peut pas provoquer d’interférences et

Содержание netwave NWKSP2

Страница 1: ... solar panels valve regulated lead acid battery outdoor enclosure solar charge controller PoE midspan injector and mounting hardware The steel outdoor enclosure has a gasket hinged lid with two tamper proof locks operated by a special key for high security The enclosure can be mounted on a two to four inch pole or wall mounted with the included mounting hardware The Solar Panels include a top of p...

Страница 2: ...mounting hardware Website For information on ComNet s entire product line please visit the ComNet website at http www comnet net Support For any questions or technical assistance please contact your sales person sales comnet net or the customer service support center techsupport comnet net Safety Only ComNet service personnel can service the equipment Please contact ComNet Technical Support The eq...

Страница 3: ... About This Guide 2 Related Documentation 2 Website 2 Support 2 Safety 2 Overview 4 Legal Information 4 Introduction 5 Pole Mounting Bracket Assembly 6 Preparing the Enclosure 8 Pole Mount 10 Solar Panel Electrical Wiring 11 Battery Installation 12 Agency Compliance 15 GPL General Public License Statement 17 ...

Страница 4: ... by any means electronic and mechanical for any purpose without the express written permission of ComNet Copyright Copyright 2014 ComNet All rights reserved Disclaimer ComNet reserves the right to make changes in specifications at any time without notice The information furnished by ComNet in this material is believed to be accurate and reliable However ComNet assumes no responsibility for its use...

Страница 5: ...pan injector and mounting hardware The steel outdoor enclosure has a gasket hinged lid with two tamper proof locks operated by a special key for high security The enclosure can be mounted on a two to four inch pole or wall mounted with the included mounting hardware The Solar Panels include a top of pole mount requiring a 4 diameter pole A side of pole mount is available as an optional accessory T...

Страница 6: ...OPERATION MANUAL NWKSP2 TECH SUPPORT 1 888 678 9427 Pole Mounting Bracket Assembly If mounting the enclosure to a wall you can skip this step and mount the enclosure directly to a wall using the 4 holes in the back of the enclosure Mounting Hardware ...

Страница 7: ...INS_NWKSP2_REV 07 10 14 PAGE 7 INSTALLATION AND OPERATION MANUAL NWKSP2 TECH SUPPORT 1 888 678 9427 ...

Страница 8: ...sure Attach grounding wire to the door and enclosure Remove plastic covers on copper studs Add grounding cable to the two studs and use the copper washers and nuts to secure Grounding Cable Installed Mount the DIN Rail The DIN Rail can be mounted to the door backplate or sides of the enclosure DIN Rail installed on door ...

Страница 9: ... then clip to the DIN Rail Controller and Power Injector Mounted on DIN Rail Plug the external thermal sensor into the interface of the thermal sensor on the left of the controller Thermal Sensor Plugged into Controller Insert battery platform in the enclosure The cutouts in the platform are for routing cable under the batteries Battery Platform on Floor of Enclosure ...

Страница 10: ... pole use the 6 included Stainless Hose clamps to secure the enclosure to a pole For your safety we highly recommend mounting the enclosure before installing the batteries Enclosure Mounted to Pole with Clamps Add the cable glands and drain plug to the bottom of the enclosure after mounting Battery Platform on Floor of Enclosure ...

Страница 11: ...le MC4 Connectors Connect the MC4 Male Positive Connectors from the solar panels to the MMF Connector then connect the 15 Cable with MC4 Female Connector to the Male FFM Connector and run cable thru a cable gland of the enclosure Connect the MC4 Female Negative Connectors from the solar panels to the FFM Connector then connect the 15 Cable with MC4 Male Connector to the Female MMF Connector and ru...

Страница 12: ...INS_NWKSP2_REV 07 10 14 PAGE 12 INSTALLATION AND OPERATION MANUAL NWKSP2 TECH SUPPORT 1 888 678 9427 ...

Страница 13: ...y can be installed vertically or horizontally We recommend installing on its side for ease of access Enclosure Mounted to Pole with Clamps Connect the 24 10AWG cables to the positive and negative battery posts PV Cable Connecting Battery Terminals NOTE Please apply rubber insulator to the terminals to prevent contact with the door in case of earthquake or vibration ...

Страница 14: ... Battery Cables Connected to Controller Battery Terminals Once batteries are connected to the controller connect the PV cables from the solar panels to the Solar Load terminals on the controller Solar Panel Cables Connected to Solar Load Terminals on Controller Connect the 12 Bonded Red and Black cable to the green terminal adaptor then connect the other end of the cable to the load terminals on t...

Страница 15: ...INS_NWKSP2_REV 07 10 14 PAGE 15 INSTALLATION AND OPERATION MANUAL NWKSP2 TECH SUPPORT 1 888 678 9427 Red and Black Cable Connected Green Terminal Connector left and to Load Terminals on Controller right ...

Страница 16: ...PPORT 1 888 678 9427 Insert green terminal into the Power Injector Green Terminal Connector attached to Power Injector See Solar Charge Controller User Manual for instructions on how to use the controller Solar Panel mounting instructions will be included with the mounting hardware ...

Страница 17: ...ntial area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Industry Canada This Class A digital apparatus complies with Canadian ICES 003 To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power EIRP is not more than that per...

Страница 18: ...rn Ireland Austria Belgium Denmark Finland France Germany Ireland Italy Netherlands Norway Portugal Romania Switzerland Sweden Installer Compliance Responsibility Devices must be professionally installed and it is the professional installer s responsibility to make sure the device is operated within local country regulatory requirements RoHS WEEE Compliance Statement European Directive 2002 96 EC ...

Страница 19: ... granted a license to that software under the terms of either the GNU General Public License or GNU Lesser General Public License License copies of which are available from http www gnu org licenses licenses html The Licenses allow you to freely copy modify and redistribute that software without any other statement or documentation from us ComNet will provide to anyone who contacts us at the conta...

Страница 20: ...EY LEEDS UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 INFO EUROPE COMNET NET ComNet Customer Service Customer Care is ComNet Technology s global service center where our professional staff is ready to answer your questions at any time Email ComNet Global Service Center customercare comnet net Contact Information ComNet www comnet net North America ComNet Corporate Headquarters and Customer ...