ALIGNMENT AND TROUBLESHOOTING PROCEDURES
LBI-38425A
23
5.3 RECEIVER
Alignment and Troubleshooting procedures for Receiver Circuitry on
Transmitter/Receiver Board CMN-233 are as follows:
5.3.1 Receiver
Alignment
Equipment Required:
•
RF Signal Generator (150.8 – 174 MHz)
•
DC Voltmeter
•
Frequency Counter (up to 500 MHz with 0.05 V sensitivity)
•
Audio Level Meter and Distortion Analyzer
•
4 Ohm, 6 Watt Resistor
5.3.1.1
Preliminary Adjustment
1.
Connect 13.8 VDC to P2.
2.
Set MONITOR switch to “out” position.
3.
Select desired channel.
4.
Disable Channel Guard by connecting ground to J701-7.
5.
Connect RF Signal Generator to antenna jack J1.
NOTE
Make sure the transmitter is properly aligned before aligning the receiver
.
Содержание MLS II MLSH041
Страница 1: ...LBI 38425A Maintenance Manual Service Section MLS II Highband Two Way Mobile Radios MLSH041...
Страница 21: ...ALIGNMENT AND TROUBLESHOOTING PROCEDURES LBI 38425A 21 TRANSMITTER TROUBLESHOOTING...
Страница 22: ...LBI 38425A ALIGNMENT AND TROUBLESHOOTING PROCEDURES 22...
Страница 28: ...LBI 38425A ALIGNMENT AND TROUBLESHOOTING PROCEDURES 28...
Страница 29: ...ALIGNMENT AND TROUBLESHOOTING PROCEDURES LBI 38425A 29 This Page Intentionally Left Blank...