INSTALLATION CONSIDERATIONS 

This fiber-optic link is supplied as a Standalone module. Units should be installed in dry locations protected from extremes of temperature and humidity.

CAUTION:

 

Take care not to press on any of the LEDs.

WARNING

: Unit is to be used with a Listed Class 2 power supply.

IMPORTANT SAFEGUARDS: 

A)  Elevated Operating Ambient

 - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than 

room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) 

specified by the manufacturer.

B)  Reduced Air Flow

 - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

MECHANICAL INSTALLATION INSTRUCTIONS

Содержание CWGE2SCS2

Страница 1: ...e 10 100 1000 Mbps data over multimode or single mode optical fiber The electrical interface will Auto Negotiate to a 10 100 or 1000 Mbps Ethernet rate without any adjustments The optical interface operates at a 1000 Mbps Ethernet rate These media converters are commercial grade for light industrial use Indicating LEDs are provided for confirming operating status See Figure 4 on Page 3 for LED exp...

Страница 2: ...PANEL FRONT PANEL 2 5mm Center Positive Plug Operating Voltage 9 to 12 VDC Power Consumption 2W FIGURE 3 POSSIBLE ETHERNET CONFIGURATION Ethernet IEEE 802 3 Network Element Ethernet IEEE 802 3 Network Element CWGE2SCM2 CWGE2SCM2 CAT5e 6 with RJ45 Connections CAT5e 6 with RJ45 Connections 2 OPTICAL FIBERS SC CONNECTORS MULTIMODE Ethernet IEEE 802 3 Network Element determined by user TX RX ...

Страница 3: ...is connected Flashing Packets sending receiving on TX port FDX COL On TX port full duplex mode active Off TX port half duplex mode active FX or SD On Fiber signal is detected 1000M On TX in 1000 Mbps speed Off TX in 100 Mbps speed Function DIP Switch Position 1 2 3 4 Link Fault Pass through function DIP Switches 1 and 4 must be set to opposite positions default is 1 ON 4 OFF OFF ON ON OFF Pass thr...

Страница 4: ...ocations protected from extremes of temperature and humidity CAUTION Take care not to press on any of the LEDs WARNING Unit is to be used with a Listed Class 2 power supply IMPORTANT SAFEGUARDS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be...

Отзывы: