2.4 DIP-switch
The switch provides 9 DIP-switches for configuring the relay alarm operational mode and
the ring master operational mode. The default value of Dipswitch is
OFF
.
DIP Switch No
Stat
us
Description
OFF
Disable port 1 Alarm
1
ON
Enable port 1 Alarm. If the port’s link fails, the fault LED will light up.
OFF
Disable port2 Alarm
2
ON
Enable port 2 Alarm. If the port’s link fails, the fault LED will light up.
OFF
Disable port3 Alarm
3
ON
Enable por3 t Alarm. If the port’s link fails, the fault LED will light up.
OFF
Disable port4 Alarm
4
ON
Enable port4 Alarm. If the port’s link fails, the fault LED will light up.
OFF
Disable port 5 Alarm
5
ON
Enable port5 Alarm. If the port’s link fails, the fault LED will light up.
OFF
Disable port 6 Alarm
6
ON
Enable port6 Alarm. If the port’s link fails, the fault LED will light up.
OFF
Disable port 7 Alarm
7
ON
Enable port 7 Alarm. If the port’s link fails, the fault LED will light up.
OFF
Disable port8 Alarm
8
ON
Enable port8 Alarm. If the port’s link fails, the fault LED will light up.
OFF
Disable the ring master function.
9
ON
Enable the switch as the ring master
in the X-Ring group.
[NOTE]
1. When port-alarm function is enabled, the fault LED will be on and the Alarm relay
will activate when a port failure occurs.
2. Restart the switch after the X-Ring DIP switch is set.