background image

INSTALLATION AND OPERATION MANUAL 

CNGE2+2SMS[POE][HO]

10/100/1000 MBPS INTELLIGENT REDUNDANT RING  

GIGABIT SWITCH WITH OPTIONAL POE+

The ComNet CNGE2+2SMS[POE][HO] is a four port intelligent switch with light 
management functionality. It provides two 10/100/1000Base-T(X) copper ports and 
two 100/1000Base-FX SFP ports. The CNGE2+2SMS[POE][HO] provides exclusive 
functionality for easy field deployment including DIP switch based operation of 
RSTP for creating redundant network topologies as well as preventing network video 
flooding of multicast traffic with IGMP snooping. Ports 1 and 2 can optionally supply 
up to thirty (30) watts of power per port based on the IEEE 802.3at standard. An 
optional High Output (HO) version is also available that can supply up to sixty (60) 
watts of PoE from ports 1 and 2. This product is fully compatible with the ComNet 
exclusive CopperLine® SFP modules for operation over extended distance UTP or Coax 
cable. The ComNet exclusive Port Guardian feature provides additional cyber security 
protection by enabling physical port lockout in the event that an existing cable is 
disconnected and  prevents  a potential network incursion using common spoofing 
techniques. The intrusion event is reported back to the operator using SNMP. 

This manual serves the following 

ComNet Model Numbers:

CNGE2+2SMS
CNGE2+2SMSPOE
CNGE2+2SMSPOEHO

Содержание CNGE2+2SMS

Страница 1: ...1 and 2 can optionally supply up to thirty 30 watts of power per port based on the IEEE 802 3at standard An optional High Output HO version is also available that can supply up to sixty 60 watts of P...

Страница 2: ...s 7 Indicating LEDs 10 Cables 11 Ethernet Cables 11 10 100 1000BASE T X Pin Assignments 11 SFP 13 Console Cable 13 DIP Switches 14 WEB Management 22 Configuration by Web Browser 22 System Information...

Страница 3: ...nfig 38 CNGE2 2SMSPOE HO PoE PSE Status Information 39 CNGE2 2SMSPOE HO PoE Contact Information 40 Port Guardian 41 Port Guardian CLI Reset 42 Static Multicast MAC Routing Per Port 43 Static MAC Lock...

Страница 4: ...stributor This warranty does not cover product modifications or repairs done by persons other than ComNet approved personnel and this warranty does not apply to ComNet products that are misused abused...

Страница 5: ...mNet eConsole software suite eConsole is network management software that is very effective With easy to use and intuitive interface you can easily monitor the status of the switches Software Features...

Страница 6: ...for quick feature selection 2 Redundant DC power inputs Operating Temperature 40 75 C Storage Temperature 40 85 C Operating Humidity 5 95 non condensing 2 10 100 1000Base T X Gigabit Ethernet port 2...

Страница 7: ...ng table describes the ports that are on the sides of the CNGE2 2SMS Port Description 10 100 1000Base T X RJ 45 Ethernet ports 2 10 100 1000Base T X RJ 45 fast Ethernet ports support auto negotiation...

Страница 8: ...POE HO TECH SUPPORT 1 888 678 9427 9 8 3 4 5 2 7 10 6 1 CNGE2 2SMS 1 Configuration DIP switches 2 Console Mini USB 3 LED for PWR1 4 LED for PWR2 5 LED for STATUS 6 Power Connections 7 RJ 45 Ports 8 Li...

Страница 9: ...5 3 2 9 13 1 4 10 11 CNGE2 2SMSPOEHO 1 Power connections 2 Contact IN terminal block 3 Contact OUT terminal block 4 Configuration DIP switches 5 Console Mini USB 6 LED for Power 1 7 LED for Power 2 8...

Страница 10: ...reen On DC Power Input 2 Good Off No power detected STATUS Green On Initialization passed Red On Failed 10 100 1000Base T X Ethernet ports LNK ACT Green On Port link up Blinking Data transmitting 1000...

Страница 11: ...specifications Cable Types and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100 UTP 100m 328ft RJ 45 100BASE TX Cat 5 100 UTP UTP 100m 328ft RJ 45 1000BASE TX Cat 5 Cat 5e 100 UT...

Страница 12: ...connect PC to switch The following table below shows the 10 100BASE T X MDI and MDI X port pin outs 10 100 Base T MDI MDI X pin assignments Pin Number MDI port MDI X port 1 TD transmit RD receive 2 T...

Страница 13: ...les that offer different fiber type connector type and distances Please remember that the TX port of Switch A should be connected to the RX port of Switch B Switch A Fiber Cord Switch B Console Cable...

Страница 14: ...SFP Port 3 speed Up 1000M Down 100M 7 SFP Port 4 speed Up 1000M Down 100M Switch Function Listing The switch functions may be set individually or may be combined in the following order to perform enh...

Страница 15: ..._CNGE2 2SMS_REV 02 19 13 PAGE 15 INSTALLATION AND OPERATION MANUAL CNGE2 2SMS POE HO TECH SUPPORT 1 888 678 9427 SMS MUX Disabled DIP Switch 2 in OFF Position SMS MUX Enabled DIP Switch 2 in On Positi...

Страница 16: ...n Ports 1 2 as shown Ports 1 2 are free to send traffic between each other as per a normal switch Redundant SFP RSFP Enabled DIP Switch 4 in On Position Note There is no port isolation between Ports 1...

Страница 17: ...n Ports 1 2 as shown Ports 1 2 are free to send traffic between each other as per a normal switch Redundant SFP RSFP Enabled 3rd Party Switch DIP Switch 4 in On Position Note Disabling MAC Address Lea...

Страница 18: ...preventing flooding on the local device between Ports 1 2 Ports 1 2 are isolated from each other Redundant SFP RSFP Enabled SMS MUX Enabled 3rd Party Switch DIP Switch 2 4 ON Note Disabling MAC Addre...

Страница 19: ...omNet recommends maximum number of units per ring is limited to 20 devices Numbers higher than this may cause undesired performance and are not supported by ComNet Note The unit at the control room lo...

Страница 20: ...d are not supported by ComNet Attention Central switch must be manually configured to be the root bridge This requirement is mandatory for correct performance in a multiple ring scenario Attention Com...

Страница 21: ...1 888 678 9427 IGMP RSTP Enabled DIP Switch 1 5 ON Important Note The CNGE2 2SMS supports IGMP snooping only When using the IGMP function a managed switch must be implemented within the network that i...

Страница 22: ...onfiguration through the Web browser About Web based Management An embedded HTML web site resides in the flash memory on the CPU board It contains advanced management features and allows you to manage...

Страница 23: ...678 9427 System Login 1 Launch your Web Browser 2 Type http and the IP address of the switch Press Enter 3 The login screen appears 4 Enter username and password The default username and password is...

Страница 24: ...INS_CNGE2 2SMS_REV 02 19 13 PAGE 24 INSTALLATION AND OPERATION MANUAL CNGE2 2SMS POE HO TECH SUPPORT 1 888 678 9427 Main Interface Main interface...

Страница 25: ...tion interface Label Description Switch Settings Summary table of external switch settings Web Management Enable Override the side panel switches setting to use the webpage settings instead Switch ove...

Страница 26: ...ECH SUPPORT 1 888 678 9427 Switch Port Configuration Unless you have reason to change this setting it is recommended to leave the negotiation set to auto The link segment requires forcing the settings...

Страница 27: ...NGE2 2SMS_REV 02 19 13 PAGE 27 INSTALLATION AND OPERATION MANUAL CNGE2 2SMS POE HO TECH SUPPORT 1 888 678 9427 Port Statistics Use the refresh button to update the port statistics Port Statistics inte...

Страница 28: ...tocol RSTP System configuration interface Label Description Enable RSTP Select to enable RSTP only available when the DIP switch settings have been overridden by web management mode See Page 26 Priori...

Страница 29: ...Port Configuration RSTP Port configuration interface Label Description Port Priority Configure port priority must be a multiple of 16 Port Admin Configure port Admin or Auto Edge status Port Status Su...

Страница 30: ...O TECH SUPPORT 1 888 678 9427 LLDP LLDP Link Layer Discovery Protocol function allows the switch to advertise its information to other nodes on the network and store the information it discovers LLDP...

Страница 31: ...ction selected in the Failure Action menu Active Ping Check configuration interface Label Description Enable Select to enable the active ping check function Interval Active ping check interval in seco...

Страница 32: ...sue an SNMP trap POE Reset Reboot the PoE device Trap Reset Issue an SNMP trap and then reboot the PoE device Power Down Turn off the RJ45 port PwrDwn Trap Issue an SNMP trap and then turn off the RJ4...

Страница 33: ...ON AND OPERATION MANUAL CNGE2 2SMS POE HO TECH SUPPORT 1 888 678 9427 Authentication Username and Password Configuration The username and password entered here are also used in the CLI Authentication...

Страница 34: ...how to upload the new image is located in Firmware Upgrade section on Page 51 After applying a new firmware version it is recommended that a Factory Default Reset is performed to ensure that all new...

Страница 35: ...POE HO TECH SUPPORT 1 888 678 9427 Factory Defaults Factory Defaults Reset interface This function restores the system configuration back to the factory default values All parameters will revert back...

Страница 36: ...rface This feature will perform a system reset Some system configuration changes require a system reset to take effect RSTP changes File System updates Network configuration changes IGMP changes Stati...

Страница 37: ...e IP address from the network DHCP server The default IP address will be replaced by the IP address which the DHCP server has assigned IP Address Assign the IP address that the switch will use If DHCP...

Страница 38: ...ement systems learn of problems by receiving traps or change notices from network devices implementing SNMP SNMP Config SNMP Community Configuration interface The following table describes the labels...

Страница 39: ...associated port Port Power UP Turns on PoE power to the associated port Port PD Class Displays the PoE class being used by the PoE device Force PoE Mode Enables 60 W of PoE in manual forced mode HO m...

Страница 40: ...on Label Description Output Contact The faults that trigger the output contacts are fully configurable by selecting the source s to monitor Contact Override The contacts may also be forced to an opene...

Страница 41: ...rator can issue an SNMP reset or can reset a port by using the CLI via the USB serial port In PoE models a reset can also be initiated by using one of the contact inputs Label Description Enable Enabl...

Страница 42: ...can be displayed to show any ports that are in lock out state To access the Port Guardian CLI commands connect to the CLI using the procedure described in the Command Line Interface Management section...

Страница 43: ...ast MAC Routing interface Label Description Enable Enable static multicast MAC routing MAC Addr Destination Multicast MAC address of the stream Port Number Ports to be included in the multicast route...

Страница 44: ...AC Addr MAC address of the device that is allowed to forward and receive traffic Packets will be dropped for MAC addresses not listed in the table Port Number Ports to be included in the locked list A...

Страница 45: ...INS_CNGE2 2SMS_REV 02 19 13 PAGE 45 INSTALLATION AND OPERATION MANUAL CNGE2 2SMS POE HO TECH SUPPORT 1 888 678 9427 IGMPv2 Snooping IGMPv2 Multicast Routing interface...

Страница 46: ...specific group Unregistered Flooding Allow unregistered multicast traffic to propagate across ports Assigned router port Router ports forward membership reports Multicast Groups The IP address of the...

Страница 47: ...ration interface Label Description MTU size the drop down box allows for maximum frame size the default is the maximum frame size 10 240 Not enabled defaults the maximum frame size to 1522 MTU Apply S...

Страница 48: ...onfiguration You can use USB console to manage the switch by CLI CLI Management by USB Console 115200 8 none 1 none Before configuring by USB console use a USB mini B cable to connect the switch s Con...

Страница 49: ...ct the COM port number Step 4 The COM port properties setting 115200 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control Step 5 Hit enter to initiate the conn...

Страница 50: ...ach command is available using help in front of the command name Issuing a netinfo command will display the ip address of the switch To change the network configuration using the CLI the following com...

Страница 51: ...ation click the enable Ethernet check box and adjust the IP address to the target IP 3 Click the Load Hex File and select the new firmware file Click Erase Click Program Click Verify Click run applica...

Страница 52: ...alth Check SNMP Enable Disable Ports Port Guardian Physical Port Lockout IGMP Snooping v2 SNMP Trap LLDP Static Multicast MAC Routing Static MAC Lock Security Active Ping Check with SNMP Trap Port Res...

Страница 53: ...2010 Radiated Emissions EN 55022 2010 Conducted Emissions EN 61000 3 2 2006 A2 2009 Harmonic Current Emissions EN 61000 3 3 2013 Voltage Fluctuations EN 61000 4 2 2009 ESD EN 61000 4 3 2006 A2 2010 Ra...

Страница 54: ...INS_CNGE2 2SMS_REV 02 19 13 PAGE 54 INSTALLATION AND OPERATION MANUAL CNGE2 2SMS POE HO TECH SUPPORT 1 888 678 9427...

Страница 55: ...CH SUPPORT 1 888 678 9427 INFO COMNET NET 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 INFO EUROPE COMNET NET MECHANICAL INSTALLATION INSTRUCTIONS...

Отзывы: