MEChANICAL INSTALLATION INSTRUCTIONS

INSTALLATION CONSIDERATIONS 

This switch is supplied as a Standalone/Rack module. units should be 

installed in dry locations protected from extremes of temperature and 

humidity. 

NOTE:  Although the units may be mounted inside a ComNet  

rack they cannot be powered from the built-in rack PSU;  

they must be powered by an external 48vDC PSU instead.

C1-US, C1-EU, C1-AU OR C1-Ch CARD CAGE RACKS

 

CAUTION:

 Although the units are hot-swappable and may be installed 

without turning power off to the rack, ComNet recommends that the 

power supply be turned off and that the rack power supply is disconnected 

from any power source. 

Note:

 Remove electrical connector before 

installing in card cage rack.

1.  Make sure that the card is oriented right side up, and slide it into the 

card guides in the rack until the edge connector at the back of the card 

seats in the corresponding slot in the rack’s connector panel. Seating 

may require thumb pressure on the top and bottom of the card’s front 

panel.

CAUTION:

 

Take care not to press on any of the LEDs.

 

2.  Tighten the two thumb screws on the card until the front panel of the 

card is seated against the front of the rack.

WARNING

: unit is to be used with a listed Class 2 or lPS power supply.

IMPORTANT SAFEGUARDS: 

A)  Elevated Operating Ambient

 - If installed in a closed or multi-unit rack 

assembly, the operating ambient temperature of the rack environment may 

be greater than room ambient. Therefore, consideration should be given to 

installing the equipment in an environment compatible with the maximum 

ambient temperature (Tma) specified by the manufacturer.

B)  Reduced Air Flow

 - Installation of the equipment in a rack should be such 

that the amount of air flow required for safe operation of the equipment is not 

compromised.

FIGURE A

Dimensions are for a standard ComNet™ one slot module

.156 [3.96 mm]

.313 [7.95 mm]