Comnet CLRFE1EOCE/M Скачать руководство пользователя страница 3

INS_CLRFE1EOCX/M-REV-   12/23/14   PAGE 3

INSTALLATION AND OPERATION MANUAL 

CLRFE1EOC(E,P)/M SERIES

TECH SUPPORT: 1.888.678.9427

APPLICATION DIAGRAMS

PoE Pass-Through Mode

Non-PoE Mode

IMPORTANT NOTE. PLEASE READ.

 The applications are shown as general representations only and are not intended to show detailed network topologies. Your actual network will differ, 

requiring changes or perhaps additional network equipment to accommodate the systems as illustrated. 

Please contact ComNet’s Design Center to discuss your specific requirements.

PoE  

Ethernet Switch 

or Midspan

Local

Remote

CLFE1EOC

CLRFE1EOCP/M

PoE Camera

Ethernet  

Switch

Local

Remote

Power

Power

Power

CLFE1EOC

CLRFE1EOCE/M

IP Camera

Ethernet Connection

PoE Power

Extended Connection

TABLE 1 – APPROXIMATE MAXIMUM EXTENDED DISTANCES

1

Media

COAX - RG59/U

Camera Data Rate

10M

100M

Non-PoE Camera

1

5,000 ft 

1,524 m

2,000 ft 

610 m

PoE CLASS2 Camera (6.5W)

1

3,000 ft 

914 m

2,000 ft 

610 m

PoE CLASS3 Camera(13W)

1

 

(10W in Pass-Through mode)

750 ft 

228 m

750 ft 

228 m

1

   Distance figures are based on a 50V PSE PoE power source, and external power supplies for the extenders. Distance figures are obtained using 

in-house testing mirroring installations. Factors such as coaxial/copper cable quality, the number of connectors/splices in the cable run, the use 

of PoE, and environmental conditions encountered within the installation may affect the actual transmission distance, and should be taken into 

consideration. Due to advanced negotiation signaling required in IEEE 802.3at applications, Pass-through applications are limited to IEEE 802.3af PD 

devices only.

1   Mixed PoE and Non-PoE systems can be implemented.

2   All Non-PoE systems require local power.

3   PoE powered operation requires that a PoE Camera be connected, and that the camera power requirements are understood.

4  Lower data rates generally provide longer operating distances.

APPLICATION NOTES

Содержание CLRFE1EOCE/M

Страница 1: ...ended distance coaxial cable Available in both standard and PoE applications the mini CopperLine units are automatically configured as remote units Bi color Red Green LED indicators are provided for rapidly ascertaining equipment operating status Table 3 on Page 4 describes the LED indicators for each light on the unit The mini CopperLine units are stand alone with a small footprint for use where ...

Страница 2: ...P M SINGLE CHANNEL COAX REMOTE PASS THROUGH POE POWERED UNIT EXT DISTANCE EXT DISTANCE ETHERNET ETHERNET FRONT FRONT REAR REAR Power 9 to 36 VDC OR 24 VAC Power Consumption 1 5 W Power Supplied via PoE from Head End Power Consumption 1 5 W Black AC or DC Black w White Stripe AC or DC 10 100 data rate DIP switch See Installation Instructions Step 1 10 100 data rate DIP switch See Installation Instr...

Страница 3: ...1 5 000 ft 1 524 m 2 000 ft 610 m PoE CLASS2 Camera 6 5W 1 3 000 ft 914 m 2 000 ft 610 m PoE CLASS3 Camera 13W 1 10W in Pass Through mode 750 ft 228 m 750 ft 228 m 1 Distance figures are based on a 50V PSE PoE power source and external power supplies for the extenders Distance figures are obtained using in house testing mirroring installations Factors such as coaxial copper cable quality the numbe...

Страница 4: ...w and Troubleshooting Guide if corrective action is needed See figures beginning on page 6 for LED configurations for each model Table 3 Indicating LEDs PWR Ethernet Link Ethernet Activity EXT LNK GREEN Power Applied Activity Detected 10Mbps YELLOW Link Established 100Mbps OFF Power Off No Link No Activity No Link TABLE 4 TROUBLESHOOTING GUIDE Problem Steps to Take Indicating LEDs not lighting Non...

Страница 5: ...6810 TM INSTALLATION CONSIDERATIONS The CLRFE1EOC E P M is supplied as a standalone surface mount mini size module Units should be installed in dry locations protected from extremes of temperature and humidity WARNING Unit is to be used with a Listed Class 2 power supply IMPORTANT SAFEGUARDS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient tem...

Отзывы: