background image

www.commscope.com 

 

860508548 

Issue 3, October 2013 

 

 

 

3.  To place conductors, hold the pair down on the 

termination position and bend it for easy grasp as 
shown above. Then untwist the pair in a counter-
clockwise direction enough to open it up. 

4.  Push conductors down into slot 

positions (check color codes). 

 

Maintain pair twist up to the 
opening for the slots. 

 

Orange pair

Blue pair

Green pair

Brown pair

Ensure that front pairs

are tightly routed

 

5.  (T568B wiring shown) On the 

Direct

  cable end, place Orange and Blue pairs first, then place Green and 

Brown pairs. 

 

 

 

 

 

 

 

 

 

Page 3 of 5 

Содержание UNJ10G

Страница 1: ...427 Replacement 110 blade for D 914 impact tool 760122713 Module removal tool quantity of 5 860333673 Hand termination tool hand puck 405423260 KS 22035 L2 spudger tool How to Contact Us To find out more about CommScope products visit us on the web at http www commscope com For technical assistance Within the United States contact your local account representative or technical support at 1 800 344...

Страница 2: ...until the jacket is snug against the rear housing Outer pairs should sweep around the inside pairs and not be pulled into them Direct Cable End Reverse Cable End Orange pair Green pair Brown pair Blue pair Brown pair Orange pair Green pair Blue pair 1 Each cable end has two pairs routed into the holes and two pairs routed over the top without crossover or rearrangement On the Direct cable end the ...

Страница 3: ...ir in a counter clockwise direction enough to open it up 4 Push conductors down into slot positions check color codes Maintain pair twist up to the opening for the slots Orange pair Blue pair Green pair Brown pair Ensure that front pairs are tightly routed 5 T568B wiring shown On the Direct cable end place Orange and Blue pairs first then place Green and Brown pairs Page 3 of 5 ...

Страница 4: ... On each cable end one of the two pairs fed in through the holes is pulled back for the rear positions Check label color codes Conductor Seating and Cutting Impact tool on HI setting with M110 cutting blade Hand puck Pliers Trim pairs flush Fine edge cutters 1 Use impact tool on HI setting with M110 cutting blade to punch conductors straight down into slots When using the impact tool the hand puck...

Страница 5: ...es of module and press firmly 2 The module can then be removed from the back Inspection or Repair of Termination Note To enable inspection or repair the wiring cap can be released from the module using the removal tool A spudger tool can then be used to remove conductors for repair 1 Insert end of removal tool into slot under wiring cap and pivot it forward to release cap Removal tool Insert end o...