9.3.3.
CTU-L - aramid yarn
9.3.3.1.
Cut the aramid yarn to a length of 80mm (3.15’’).
9.3.3.2.
Bend the selected metal band around the cable
while maintaining the centerlines (centerline of the metal
band on the center of the cable). Make sure both ends of the
metal band have equal lengths.
80mm
3.15’’
9.3.2.
CTU-L - dual strength member
9.3.2.1.
Cut one of the two strength members to a length
of 30mm (1.18’’). To mark this distance, the line on the side of
the CTU can be used.
9.3.2.2.
Remove the other strength member completely
(cut it flush with the cable jacket).
9.3.2.3. Proceed with steps 9.3.1.2 until 9.3.1.5 to secure
the cable jacket and the strength member to the CTU. Po
-
sition the cable such that the remaining strength member is
closest to the CTU.