background image

Instruction Sheet:

SYSTIMAX 360™ iPatch

®

 1100 Type Panel

Installing Panels

1

Panels are shipped with the cabling labels for B wiring already 
installed. If the installation uses A wiring, insert the cabling 
labels for A wiring in the slots on the back of the panels. Make 
sure that the labels are oriented with the right side up (Figure 1).

2

Make sure that the panel bus jumpers are firmly connected to 
the panels (Figure 2).

3

Install the panels on the rack using the 4 screws provided 
(Figure 3). Be careful not to pinch the panel bus jumpers 
between the panels and the rack.

4

Snap the decorative bezels onto the front of the panels. 
(Figure 4).

5

Remove the adhesive backing from the cable retainers on the 
panel bus jumpers.

6

Connect the panel bus connector on each jumper to the 
nearest connector on the panel bus, folding the jumper as 
shown (Figure 5). Press the cable retainers against the rack.

Figure 1

Inserting the Cabling Label

Figure 2

Checking the Panel Bus Jumper

Figure 3

Mounting the Panels

Figure 4

Installing the Decorative Bezel

Cabling label

Check the panel bus jumper here.

Mounting screws

Decorative bezel

Note: 

The connector is keyed. The polarized tab on the jumper 

connector fits into the opening in the header connector on the 
panel bus.

Important: 

For 2U panels, connect both panel bus jumpers.

Cabling Panels

Figure 6 identifies the IDC (position) numbers and pair numbers for 
cabling panels. Table 1 indicates the conductor colors for 
EIA-T568A and EIA-T568B wiring applications.       

1

Cable each panel. Use a Termination Manager to terminate 
each 4-pair cable, following the Termination Manager 
installation instructions provided with the panel.

Note: 

The Termination Manager provides pair-twist control and 

strain relief features to the rear termination area of the panel.

continued

Figure 5

Connecting and Routing the Panel Bus Jumpers

Figure 6

Cable IDC Numbers and Pair Numbers—Rear View of Panel

Table 1

Cable Terminations

IDC#

A Wiring

B Wiring

1

W/BL

W/BL

2

BL/W

BL/W

3

W/G

W/O

4

G/W

O/W

5

W/O

W/G

6

O/W

G/W

7

W/BR

W/BR

8

BR/W

BR/W

Panel bus

Fold the panel bus 
jumper as shown.

Panel bus

Panel bus jumper

Cable retainer

Cable
retainer

Polarized tab

Panel bus
jumper

Pair Numbers

Position Numbers

Position Numbers

Pair Numbers

A Wiring

B Wiring