6.3
Connecting the HMFOC connector
6.3.1
Remove dustcaps
1 Use a 216B key tool to unscrew the dust cap.
Note:
The 216B key tool is not included.
2 Unscrew the coupling nut from the cable connector dust cap.
3 Pull the dust cap off.
Note:
Field personnel must take care when proceeding to remove dust caps on the full size hardened connector at
the adapter plugs or cables, to prevent contaminant particles entering to the adapters or connector end-face.
6.3.2
Install the HMFOC connector
1 Find the alignment keys on the adapter port (square notch in the thread area) and on the connector (groove). And
push the plug connector in the jack of the adapter port until it seats.
2 Thread the cable connector’s coupling nut onto the thread of the adapter port until it is finger tight.
page 8 / 11
© 2021 CommScope, Inc. All Rights Reserved