3.4 Disconnecting Drop Cable from Mini-OTE Optical Port

Use the following procedure to disconnect a drop cable from an optical port on the Mini-OTE terminal:

1.

Unscrew the optical port dust cap from the drop cable dust cap (see 

Figure 7

).

2.

Unscrew the drop cable connector coupling nut from the optical port (see 

Figure 6

).

3.

Inspect the optical port dust cap O-ring for dryness and apply O-ring lubricant (MST-ACC-
LUBE1) to the O-ring if dry. For the procedure, refer to 

Section 5 on page 9.

4.

Thread the optical port dust cap into the optical port and tighten using the 216B key tool (see 

Figure 5

).

5.

Inspect the drop cable connector O-rings for dryness and apply O-ring lubricant (MST-ACC-
LUBE1) to each O-ring if dry. For the procedure, refer to 

Section 5 on page 9.

6.

Thread the drop cable dust cap onto the drop cable connector coupling nut and tighten until 
finger tight (see 

Figure 4

).

4

Maintenance of Mini-OTE 300 Terminals

Maintenance for the Mini-OTE terminal is limited to cleaning the hardened adapters as needed to maintain
optimal performance, lubricating O-rings that may become dry, or replacing a damaged optical connector.

4.1 Drop Cable Connector Cleaning Procedure

Cleaning kit (FHD-ACC-CLNKIT1) is required for this procedure. Use the following procedure to clean the
drop cable connector:

1.

Unscrew the drop cable connector dust cap from the end of the drop cable connector.

2.

Examine the end of the drop cable connector and determine which is the high side and which is 
the low side of the connector end-face as shown in 

Figure 8

.

Danger!

Exposure to laser radiation can seriously damage the retina of the eye. Do not look into the 
ends of any optical fiber. Do not assume the laser power is turned-off or that the fiber is 
disconnected at the other end.

Note:

Use the approved local cleaning device that has slots for a hardened connector shroud.

Содержание Mini-OTE 300 Tap

Страница 1: ... accelerates fiber deployment for new subscriber activation and service minimizing labor costs Each terminal is delivered with the tap pre installed in the terminal and all feeder and drop ports are sealed with a plug The terminal housing is closed and secured to prevent damage to internal splices The unit is designed for installation in pedestal hand hole pole and strand mount applications Access...

Страница 2: ...re for mounting the Mini OTE 300 in strand mount applications and some pedestal applications depending on the pedestal design Figure 2 shows the mounting options Figure 2 Mounting Options Table 1 Mini OTE Ports Row 1x2 Tap 4 Port Terminal 1x4 Tap 8 Port Terminal 1x8 Tap 12 Port Terminal 1 Port 1 2 Drop Outputs Port 3 Tap Input Port 4 Tap Thru Port 1 N A Port 2 N A Port 3 Tap Input Port 4 Tap Thru ...

Страница 3: ...description of the connector and adapter components and provide instructions for connecting or disconnecting the drop cable to from the optical ports 3 1 Connector Components The basic components of the drop cable connector are shown in Figure 4 The dust cap threads onto the connector coupling nut A pair of O rings on the connector body provide a tight seal when the dust cap is in place A pulling ...

Страница 4: ...ot insert all the way to the bottom of the port rotate drop cable connector slightly to either side until it slides freely into place 7 Thread the drop cable connector coupling nut into the optical port and tighten coupling nut until finger tight 8 Inspect the optical port dust cap O ring see Figure 4 on Page 3 for dryness and apply O ring lubricant to the O ring if dry MST ACC LUBE1 For the proce...

Страница 5: ...TC 96203 IP Installation Instructions www commscope com Page 5 of 10 Figure 6 Connecting Drop Cable to Mini OTE Optical Port Figure 7 Dust Caps 23586 B OPTICAL PORT DUST CAP DROP CABLE DUST CAP ...

Страница 6: ...ap onto the drop cable connector coupling nut and tighten until finger tight see Figure 4 4 Maintenance of Mini OTE 300 Terminals Maintenance for the Mini OTE terminal is limited to cleaning the hardened adapters as needed to maintain optimal performance lubricating O rings that may become dry or replacing a damaged optical connector 4 1 Drop Cable Connector Cleaning Procedure Cleaning kit FHD ACC...

Страница 7: ...the cleaning tape and with the high side of the connector pointing in the direction of cleaning as shown in Figure 9 6 With light pressure slide the connector end face once across the tape in the direction shown using a smooth linear motion Do not press too hard and do not repeat the cleaning motion with the same tape Note The drop cable connector uses angled SC type connectors Make sure the high ...

Страница 8: ...Using a 216B key tool unthread the optical port dust cap from the optical port adapter 2 Locate the dry swabs that are provided with the connector adapter cleaning kit 3 Insert a dry swab into the adapter as shown in Figure 10 4 While applying light pressure against the connector end face rotate the dry swab 360º three times 5 Dispose of the dry swab after use 6 When the connector end face and ada...

Страница 9: ... dust cap are lubricated when shipped from the factory to prevent damage during installation If the O rings become excessively dry they may require additional lubrication to prevent damage Remove the O rings from the connector or dust cap and apply a small amount of lubricant directly to each ring Then reinstall the O rings on the connector or dust cap Apply only the recommended O ring lubricant M...

Страница 10: ...ns www commscope com 6 Product Support To find out more about CommScope products visit us on the web at www commscope com For technical assistance customer service or to report any missing damaged parts visit us at http www commscope com SupportCenter ...

Отзывы: