![CommScope ICX7400-1X40GQ Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/commscope/icx7400-1x40gq/icx7400-1x40gq_hardware-installation-manual_2643843081.webp)
Ruckus ICX 7450 Switch Hardware Installation Guide
79
Part Number: 53-1003899-09
Power consumption (maximum configuration)
All 1 G and two 10 G ports are linked up (no other port links), loading with 100 percent traffic rate and 100 percent PoE load. 2 PSUs,
two fan FRUs, 4x10GC uplink, no stacking module, fans at high speed.
ICX7450-32ZP: 24 1-Gig + 8 2.5Gig and Slot1: Empty, Slot2: 4x10GF, Slot3: 4x10GF are linked UP, 100% traffic and PoE load.
ICX 7450-24P
95.3 W
325 BTU/hr
94.1 W
321 BTU/hr
82.6W
282 BTU/hr
1 x 1000 W AC
1 x 510 W DC
1 PSU,
no PoE load.
112.9 W
386 BTU/hr
111.7 W
381 BTU/hr
87.58 W
291 BTU/hr
1 x 1000 W AC
1 x 510 W DC
2 PSUs,
no PoE load
ICX 7450-32ZP
120.46 W
411.14 BTU/hr
118.59 W
404.76 BTU/hr
105.27 W
359.29 BTU/hr
1 x 1000 W AC
1 x 510 W DC
1 PSU,
no PoE load.
130.57 W
445.65 BTU/hr
128.32 W
437.97 BTU/hr
109.31 W
373.08 BTU/hr
2 x 1000 W AC
2 x 510 W DC
2 PSUs,
no PoE load
ICX 7450-48
117.6 W
402 BTU/hr
115.9 W
442 BTU/hr
107.6 W
367 BTU/hr
1 x 250 W AC
1 x 510 W DC
1 PSU
129.4 W
451 BTU/hr
128.4 W
438 BTU/hr
115.94 W
396 BTU/hr
1 x 250 W AC
1 x 510 W DC
2 PSUs
ICX 7450-48P
129.7 W
443 BTU/hr
143 W
488 BTU/hr
115.1W
393 BTU/hr
1 x 1000 W AC
1 x 510 W DC
1 PSU,
no PoE load.
128.2 W
438 BTU/hr
141.1 W
482 BTU/hr
118.82W
406 BTU/hr
1 x 1000 W AC
1 x 510 W DC
2 PSUs,
no PoE load
ICX 7450-48F
141.4 W
420 BTU/hr
139.6 W
477 BTU/hr
129.2W
441 BTU/hr
1 x 250 W AC
1 x 510 W DC
1 PSU
152.8 W
522 BTU/hr
151.6 W
518 BTU/hr
132.78W
474 BTU/hr
1 x 250 W AC
1 x 510 W DC
2 PSUs
Model name
(Input power ±5%)
@100 VAC
input
@200 VAC
input
@-48VDC
Minimum number
of power supplies
Notes
ICX 7450-24
119.7 W
409 BTU/hr
118.5 W
405 BTU/hr
113.8 W
388 BTU/hr
1 x 250 W AC
1 x 510 W DC
1 PSU
134.9 W
461 BTU/hr
133 W
454 BTU/hr
125.24 W
428 BTU/hr
1 x 250 W AC
1 x 510 W DC
2 PSUs
ICX 7450-24P
947 W
3232 BTU/hr
919 W
3137 BTU/hr
387.2 W
1322 BTU/hr
1 x 1000 W AC
1 x 510 W DC
1 PSU
1402 W
4785 BTU/hr
1374 W
4690 BTU/hr
669.06 W
2284 BTU/hr
2 x 1000 W AC
2 x 510 W DC
2 PSUs required
for PoE loading
Model name
(Input power ±5%)
@100 VAC Input
@200 VAC Input
@-48VDC
Minimum number
of power supplies
Notes