Ruckus ICX 7450 Switch Hardware Installation Guide
27
Part Number: 53-1003899-09
•
Grounding: Rack-mounted equipment should be properly grounded. Particular attention should be given to supply connections
other than direct connections to the mains electricity supply.
To mount the product into a four-post rack, you can order the XBR-R000295 four-post rack kit. For the procedure to install this kit, refer
to
“Installing the 1U, 1.5U, and 2U Universal Kit for Four-Post Racks (XBR-R000295)”
Two-post rack mount installation
The Ruckus ICX 7450 can be installed in a two-post rack in various mounting positions, as shown in
.
FIGURE 15
Two-post rack mounting positions
NOTE
Use the following procedure when installing the Ruckus ICX 7450 in a two-post rack. For four-post racks, follow the procedure
in
“Installing the 1U, 1.5U, and 2U Universal Kit for Four-Post Racks (XBR-R000295)”
Use the following steps to mount the Ruckus ICX 7450 in a two-post rack.
1.
Remove the rack mount kit from the shipping carton. The kit contains the following items:
•
Two L-shaped mounting brackets
•
Eight 8-32 x 5/16 in., panhead Phillips screws
2.
Attach the mounting brackets to the sides of the device as illustrated in
using the 8-32 x 5/16 in. screws.
NOTE
Be sure to use only the screws included in the Ruckus ICX 7450 kit.
1
Front flush mount
4
Reverse mid-mount
2
Reverse-front mount
5
Rear mount
3
Front mid-mount
6
Two-post rack, side view